Descrição
O que está incluído
- Zeiss CIRRUS HD-OCT Model 4000 with integrated computer and 15-inch display
- Windows 10 operating system
- Mesa elétrica
- Garantia de 1 ano da Digital Eye Center
Condição e garantia
Recondicionado. This Cirrus 4000 is a refurbished unit running Windows 10 and ships on an electric table. Covered by a garantia de 1 ano em peças e mão de obra.
Optional licensed features on the Cirrus 4000 platform, such as Ganglion Cell Analysis, Guided Progression Analysis, FastTrac retinal tracking and anterior segment imaging, vary from unit to unit. Fale conosco and we will confirm the license list of this unit before you buy.
Zeiss Cirrus 4000 OCT: OCT de domínio espectral recondicionado
A Zeiss Cirrus 4000 OCT is a spectral-domain OCT that captures 27,000 A-scans per second with 5 µm axial resolution in tissue. Dense data cubes such as the 512 × 128 Macular Cube and the 200 × 200 Optic Disc Cube give retina and glaucoma clinics reproducible thickness maps and cross-sections from a single acquisition.
Unlike the compact Model 400, this refurbished Zeiss Cirrus 4000 OCT adds a line-scanning ophthalmoscope that shows a live 36° × 30° fundus image during alignment and during the scan, so the operator can see exactly where each cube lands. The computer and 15-inch display are built into the instrument, which keeps the footprint small on its electric table.
A Biblioteca Nacional de Medicina dos EUA indexes a study in Ophthalmology (2011) showing that Cirrus HD-OCT optic nerve head parameters discriminate normal from glaucomatous eyes, supporting the platform’s role in routine glaucoma assessment.
Por que os consultórios escolhem o Cirrus 4000
- 27.000 A-scan por segundo — fast spectral-domain acquisition with 1024 points per A-scan and 2.0 mm scan depth in tissue.
- Resolução axial de 5 µm — clear separation of retinal layers for macular and nerve fiber layer assessment.
- Live LSO fundus view — a line-scanning ophthalmoscope image refreshes above 20 Hz during alignment and during the OCT scan.
- Dense data cubes — Macular Cube 512 × 128 and Optic Disc Cube 200 × 200 capture the whole region instead of isolated lines.
- HD 5 Line Raster — high-definition cross-sections for detailed review of macular pathology.
- Low 2 mm minimum pupil — many patients can be scanned without dilation.
- Design todo-em-um — integrated computer, 15-inch display and Windows 10 on an electric table.
- garantia de 1 ano — refurbished unit covered on parts and workmanship.
See the Zeiss CIRRUS HD-OCT in Action
This overview from ZEISS walks through the CIRRUS HD-OCT platform that the Cirrus 4000 belongs to.
Aplicações clínicas
- Glaucoma assessment — RNFL thickness and optic nerve head measurements from the Optic Disc Cube.
- Edema macular diabético — macular thickness maps to document and follow retinal swelling.
- Degeneração macular associada à idade — cross-sectional imaging of drusen, fluid and RPE changes.
- Macular hole and epiretinal membrane — HD 5 Line Raster scans to stage vitreomacular interface disease.
- Oclusão da veia retinal — thickness monitoring of associated macular edema over time.
Para quem é
- Optometry practices adding their first spectral-domain OCT.
- Ophthalmology and glaucoma clinics needing a second Cirrus for a satellite office.
- Practices replacing an older time-domain OCT with a Cirrus platform.
- Clinics that want a live fundus view during scanning without moving to a higher-tier model.
Especificações técnicas
| Especificação | Detalhe |
| Fabricante | Carl Zeiss Meditec |
| Modelo | CIRRUS HD-OCT Model 4000 |
| Tecnologia | OCT de domínio espectral (SD-OCT) |
| Fonte de luz | Diâmetro de diodo superluminescente (SLD), 840 nm |
| Velocidade de digitalização | 27.000 A-scan por segundo |
| Profundidade da imagem A-scan | 2.0 mm (in tissue), 1024 points |
| Resolução axial | 5 µm (no tecido) |
| Resolução transversal | 15 µm (no tecido) |
| Imagens do fundo do olho | Line-scanning ophthalmoscope (LSO), 750 nm, 36° × 30° field, frame rate above 20 Hz, live during alignment and during the OCT scan |
| Iris imaging | CCD camera, 1280 × 1024 |
| Scan protocols | Macular Cube 512 × 128, Optic Disc Cube 200 × 200, HD 5 Line Raster |
| Pupila mínima | 2 mm |
| Fixação | Internal and external; internal fixation focus −20 D to +20 D |
| Computer and display | Integrated computer with 15-inch color flat-panel display |
| Sistema operacional | Windows 10 |
| Dimensões | 65 L × 44 W × 53 H cm |
| Peso | 38 kg (83 lb) |
| Elétrica | 100/120 V, 50–60 Hz, 5 A or 220/240 V, 50–60 Hz, 2.5 A |
| Mesa | Mesa elétrica, incluída |
| Condição | Recondicionado |
| Garantia | Garantia de 1 ano da Digital Eye Center para peças e mão de obra |
Compare Refurbished OCT Options
| Característica | Zeiss Cirrus 4000 (this unit) | Zeiss Cirrus 400 | Optovue iVue 2ª Geração | Zeiss Cirrus 500 |
| Velocidade de digitalização | 27.000 A-scan/s | 27.000 A-scan/s | 26.000 varreduras A/segundo | 27.000 A-scan/s |
| Axial resolution (in tissue) | 5 µm | 5 µm | 5,0 µm | 5 µm |
| Resolução transversal | 15 µm | 15 µm | 15 µm (retina) | 15 µm |
| Visão do fundus | Oftalmoscópio de leitura de linhas, 36° × 30° | Live OCT Fundus, 36° × 22° | OCT en face, 21° × 21° | Live OCT Fundus image |
| Sistema operacional | Windows 10 | Windows 10 | Windows 7 | Windows 10 |
| Mesa | Mesa elétrica | Mesa elétrica | Mesa | Mesa elétrica |
| Condição | Recondicionado | Recondicionado | Recondicionado | Recondicionado |
| Garantia | 1 ano | 6 meses | 1 ano | 6 meses |
| Preço | $14,300 | $11,400 | $15,400 | $20,900 |
Need anterior segment imaging? The Kit de lentes para segmento anterior Zeiss para Cirrus OCT works with the Cirrus 4000 on units with the anterior segment license. For a newer Cirrus platform at the same scan speed, see the refurbished Zeiss Cirrus 500.
Tem alguma dúvida sobre o OCT Zeiss Cirrus 4000? Fale conosco para consultar disponibilidade e detalhes de envio.