Topcon KR 800 Autorefractor Keratometer

Topcon KR 800 Specifications

Wide 8.5-inch Touchscreen Control Panel

The new KR-800/RM-800 is equipped with a wide 8.5 inch color touchscreen panel featuring clear, easy to read icons allowing the operator full control of the unit during the measuring process

Smooth Movements

Topcon’s ability to engineer a weight reduction of approximately 23% has contributed to a smoother operation of the unit when using the X-Y control lever.

This all contributes to a more fluid measuring process and a more accurate end result.

One Touch Lock

The KR-800 is fitted with a quick and easy to use lock.

Easy Load Printer

The printer on the new units saves you time by eliminating the need to load new printer rolls. You simple drop the new roll in and print.

 

Diaton Tonometer (non-corneal)

–> Latest Article from Helio – Diaton tonometer yields IOP readings without corneal contact

The Diaton tonometer is the only one in the market that measures the intraocular pressure through the eyelid.

This unique methodology provides a new level of simplicity and safety of tests.

Diaton tonometer is a hand held non contact tonometer device measuring IOP through the eyelid and over the sclera with no contact to the cornea & causing no discomfort to the patient.  This  tonometer masures IOP within seconds without the need for anesthesia or sterilization.

Transpalpebral scleral tonometry has no other  alternative in the world. It is the best method to carry out preclinical medical research of the population and works in complicated clinical cases when it is impossible to use classical tonometry methods.

Diaton is a helpful tool for ophthalmologists faced with pediatric patients or who have corneal abnormalities such as corneal edema, erosions or keratoprosthesis.

Approved by the FDA in 2006, this instrument has been the subject of numerous clinical trials, where it has been found to be comparable with the gold standard, the Goldmann tonometer, and with many other devices.

It’s a safe & easy-to-use screening tool which makes it possible to identify patients at risk for glaucoma & refer them to ophthalmology.

Over 4.5  million people all over the world are blind due to glaucoma and this number is on the rise.

Due to the silent progression of this disease, the majority of the infected people do not even suspect they  have this disease.

The rise of IOP is one of the main factors that indicate glaucoma presence. And now, we present a safe & easy method to measure IOP that can detect glaucoma at its early stage and as a result will help to save patients’ eyes.

Compare the features of the Diaton tonometer with the most popular products in the market:

Diaton Tonometer is ideal for:

  • Screening examination
  • IOP control to select medicines
  • IOP measuring for conjunctivitis, erosions, edema and cornea dimness
  • IOP measuring after corneal surgeries
  • Immobilized patients
  • Children
  • Contact correction. No need to take out contact lenses

Fields of application:

  • Optometry
  • Ophthalmology
  • General Medical Practice
  • Neurology

Additional Information

Diaton Tonometer User Guide

Quick User Guide+ Training videos

Frey Slit Lamp Digital Imaging System


Main Features: Frey Slit Lamp Digital System

  • AMOLED 5’ touchscreen
  • Video streaming to multiple devices
  • CMOS Image Sensors with a 3.45 μm Pixel
  • 128 GB internal high-endurance flash storage
  • HDR & Global Shutter Function for high-picture-quality imaging
  • Photo & video capture
  • Photos: 2508×1536
  • HD video: 960×720
  • Bluetooth 4.2/ Wi-Fi AC
  • Color Depth: up to 12 BPP
  • Automatic L/R eye detection

Multiple Screens Streaming

Now you can stream images and videos across multiple devices.

The Frey SLI-200 digital system allows you to collaborate with other healthcare professionals, share knowledge, discuss diagnoses, and quickly improve clinical outcomes in real-time.

Ideal for general practices and educational and training institutions. Video streaming and photo sharing enhance clinical collaboration and education.

Amoled Screen

Our AMOLED screen provides superb image quality, better contrast, higher brightness, a fuller viewing angle, and a wider color range to capture even the greatest detail of the eye.

AMOLED screens consume less power and enable Frey to simplify the unique ultra-thin design with better durability.

Stand Alone (no cables)

The SLI-200 works independently and efficiently. It does not require an external PC or any other device to operate.

All cables remain hidden in an ergonomic and minimalistic design. The eye lighting system, which can be controlled using the knob built into the lamp base, is included.

Large and Reliable Storage

Getting the results to the EHR system is essential to a doctor’s workflow. The SLI-200 simplifies and speeds up the work with 128GB internal storage enabling the storage of many heavy files. Select the most interesting photos and send them to your smartphone – without cluttering them.

Wireless!

Use our fast and reliable Wi-Fi AC or Bluetooth 4.2 to connect all your devices( PC, Smartphones, Ipads). Simplify workspace and improve clinical workflows.

Used Topcon RM 8800 Autorefractor

What’s included

  • Used Topcon RM 8800 Autorefractor
  • Power Cable
  • Instruction Manual

Used Topcon RM 8800 Specifications

  • Color liquid crystal display screen
    • The new color LCD monitor simultaneously in the used Topcon rm 8800 autorefractor displays the readings on both right and left eyes so that the operator can instantly observe all of the pertinent information. Measurement data and settings are displayed in large, color characters on the LCD monitor, dramatically enhancing the operator’s visibility
  • Faster measurement
    • The 8800 series are among the fastest auto refractors in the world. A specially designed CPU enables the 8800 series to significantly reduce the measurement time. The measurement speed is approximately 30% faster in refraction measurements. This only saves operation time but also provides more comfort to the patient.
  • Incorporated rotary prism measuring system
    • This used Topcon rm 8800 series features Topcon’s exclusive Rotary Prism Technology for unmatched accuracy and reliability.  The off-centered ring target is able to measure areas that may be occluded by a small diameter pupil. The prism angle enables a much wider area of the retina to be measured. As a results, the measurement image provides extremely reliable data. The innovative optical design incorporated into the KR/RM-8800 allows for accurate, reliable refraction measurements within a pupil as small as 2.0 mm. This means easier and more precise diagnostic results when dealing with glaucoma, asymmetric pupils or elderly patients.
  • Enlarged measurement range of astigmatism
    • With Topcon’s innovative optical design, the 8800 series auto refractometers and auto kerato-refractometers offer exceptional accuracy with a 20% wider cylindrical measuring range. The new 8800 series’ wider range allows measurements to be obtained on patients with up to ±10.00D (from C±8.00D with a conventional TOPCON product)

 

 
Model Topcon RM 8800
Refraction measurement range
Sphere : -25D to +22D
Cylinder : 0D to ±10D
Axis : 0° to 180°
Measurable minimum pupil
diameter
2.0mm dia.
Target fixation Auto fogging
Recording of measurement value Internal printer(10 measurement values can be memorized for each right and left eye)
Monitor 5-inch type (color character display)
Power input 60VA
Dimensions 275mm(W) × 475mm(D) × 450mm(H)
Weight 20kg
PD measurement range 20mm to 85mm Measurement range (1mm step)