Topcon SL-D701 LED Slit Lamp w/ Haag Streit AT 900 Tonometer – Used

SKU: US-SL-TOP-SL-D701

US$5,280.00

Used Topcon SL-D701 LED slit lamp with Haag-Streit AT 900 applanation tonometer. 5-step magnification (6×–40×), LED illumination, 4 filters. 90-day warranty. Contact us.

Out of stock

Description

CURRENTLY SOLD OUTWe Can Source This For You

This exact unit sold recently — but we specialize in sourcing refurbished ophthalmic equipment. Typical turnaround is 2–4 weeks once we confirm availability with our partners. Request a free quote with no deposit required.

Request Availability → Free quote · No obligation · 90-day warranty when shipped

Similar Slit Lamps In Stock Now

Need a comparable slit lamp available today? These units are in stock and ready to ship with a 90-day Digital Eye Center warranty.

Prefer to wait for the Topcon SL-D701 LED Slit Lamp w/ Haag Streit AT 900 Tonometer – Used? Request availability and we’ll source one for you.

What’s Included

  • Topcon SL-D701 LED slit lamp
  • Haag-Streit AT 900 applanation tonometer
  • Power supply and cables
  • 90-day Digital Eye Center warranty

Condition & Warranty

Used. Inspected and tested for full optical and mechanical function prior to shipment. Covered by a 90-day warranty on parts and workmanship.

Topcon SL-D701 Slit Lamp — Used LED Slit Lamp with AT 900 Tonometer

Topcon SL-D701 LED slit lamp used — front view with AT 900 tonometer The Topcon SL-D701 slit lamp delivers a 5-step magnification system (6×/10×/16×/25×/40×) with LED illumination, giving eye care professionals a reliable, low-maintenance platform for anterior segment examination without the recurring cost of halogen bulb replacement. Paired with the Haag-Streit AT 900 applanation tonometer — the clinical gold standard for intraocular pressure measurement — this unit provides everything required for a complete glaucoma and anterior segment workup in a single, space-efficient setup. The Topcon SL-D701 is an excellent value for ophthalmology and optometry practices upgrading from older halogen systems or outfitting a second examination lane.

Research published in Clinical Ophthalmology (National Library of Medicine) confirms the clinical significance of anterior segment biomicroscopy parameters in identifying patients at elevated risk for glaucoma — underscoring the importance of a reliable slit lamp with integrated IOP measurement capability for comprehensive screening workflows.

Why Practices Choose the Topcon SL-D701

Topcon SL-D701 slit lamp used — 5-step magnification optics detail

  • 5-step magnification (6×/10×/16×/25×/40×) — Full range from wide-field corneal overview to 40× high-power detail, covering foreign body removal, anterior chamber evaluation, subtle lens changes, and vitreous examination in a single instrument
  • LED illumination — Cool, consistent, energy-efficient light source with no bulb replacements; color rendering stays stable over the full service life of the instrument
  • Four illumination filters — White, red-free, cobalt blue, and heat-absorbing filters support fluorescein corneal staining, vascular detail evaluation, and routine anterior segment examination
  • Haag-Streit AT 900 tonometer — The globally accepted gold standard for applanation IOP measurement; proven reproducibility and accuracy for routine glaucoma screening and monitoring
  • Compact co-axial tonometer mount — AT 900 mounts cleanly to the slit lamp arm, maintaining a tight examination lane footprint without compromising ergonomics
  • DC-4 photo documentation upgrade path — Compatible with the Topcon DC-4 camera attachment for clinical image capture when your practice is ready to add documentation capability

Clinical Applications

  • Anterior segment biomicroscopy — cornea, conjunctiva, iris, and crystalline lens evaluation
  • Applanation tonometry for IOP measurement and glaucoma screening and monitoring
  • Fluorescein staining, corneal abrasion mapping, and superficial foreign body identification
  • Gonioscopy lens examination of the anterior chamber angle
  • Contact lens fitting evaluations and follow-up assessments
  • Post-operative anterior segment review following cataract or refractive procedures

Who This Is For

  • Ophthalmology practices adding or replacing a primary examination lane
  • Optometrists upgrading from halogen slit lamps to LED
  • Ambulatory surgery centers and multi-specialty eye clinics
  • Residency programs and teaching facilities requiring reliable lane equipment

Technical Specifications

Specification Detail
Model Topcon SL-D701
Illumination LED (energy-efficient, no bulb replacement)
Magnification 5-step: 6×, 10×, 16×, 25×, 40×
Filters White, Red-free, Cobalt blue, Heat absorbing
Tonometer Haag-Streit AT 900 applanation tonometer
Photo Documentation Compatible with Topcon DC-4 camera (optional)
Condition Used
Warranty 90 days — parts and workmanship

Compare Slit Lamp Options

Feature Topcon SL-D701 w/ AT 900 Haag-Streit BQ 900 w/ AT 900 Haag-Streit BM 900 w/ AT 900 Portable Slit Lamp S2
Price $5,280 $11,000 $11,000 $1,670
Illumination LED Halogen LED LED
Magnification 5-step (6×–40×) 2-step (10×/16×) 2-step (10×/16×) 2-step (10×/16×)
Tonometer Included Yes — AT 900 Yes — AT 900 + Beam Splitter Yes — AT 900 No
Condition Used Used Used Brand New
Warranty 90 days 90 days 90 days 1 year

Also consider the Portable Slit Lamp S2 for mobile screening, house calls, or field examinations where a table-mounted unit is impractical.

Questions about the Topcon SL-D701? Contact us for availability and shipping details.

Additional information

Weight 50 lbs

You may also like…