Description
What’s Included
-
Ellex Medical Laserex Integre SP Main Console (Integrated 532 nm Laser Cavity & Slit Lamp Biomicroscope)
-
Heavy-Duty Laser Firing Footswitch
-
Laser Safety Interlock Connector & Operator Key
-
Power cord and standard connection accessories
-
90-day warranty
Condition & Warranty
Used. This Ellex Medical Laserex Integre SP Ophthalmic Laser has been thoroughly serviced, laser-bench calibrated, and clinically tested by certified ophthalmic laser technicians. The 532 nm diode-pumped solid-state (DPSS) laser cavity delivers stable, verified energy output across its full power range with uniform spot homogeneity and zero thermal drift. The 635 nm red aiming beam aligns coaxially with the treatment beam across all spot sizes. The integrated Galilean slit lamp optics are crystal-clear and free of internal haze or scratches, and the ambidextrous micromanipulator operates smoothly with precision damping. Covered by a 90-day warranty on parts and workmanship.
Ellex Medical Laserex Integre SP — Used Integrated 532 nm Photocoagulation Workstation
The Ellex Medical Laserex Integre SP is an acclaimed, all-in-one 532 nm green solid-state photocoagulator engineered specifically for retinal photocoagulation, laser trabeculoplasty, and iridotomy procedures. Unlike traditional standalone laser consoles that rely on fragile external fiber-optic cables, the Integre SP houses both the laser diode cavity and optical delivery pathway directly inside a purpose-built slit lamp architecture. This true integrated design eliminates exposed fiber cables that can bend, tangle, or degrade, maximizing clinical uptime and long-term reliability.
Built around an optimized posterior-segment slit lamp with a 10∘10^\circ stereoscopic convergence angle, the Integre SP provides superior depth perception, an enhanced red reflex, and wide peripheral fundus visualization. Its proprietary laser cavity delivers uniform energy distribution across the entire spot diameter—eliminating central hotspots to create consistent, predictable therapeutic burns. Paired with a continuously variable spot size control and a vibration-damped ambidextrous micromanipulator, this pre-owned workstation provides retinal and glaucoma specialists with exceptional procedural control.
Research published in the National Library of Medicine demonstrates that 532 nm frequency-doubled solid-state green lasers with uniform top-hat beam profiles provide high absorption in melanin and hemoglobin while minimizing collateral thermal spread, resulting in consistent chorioretinal adhesion during panretinal and focal photocoagulation.
Why Practices Choose the Ellex Laserex Integre SP
-
True Integrated All-in-One Architecture — Channels the laser beam directly through the slit lamp optics with zero exposed fiber-optic or external power cables, preventing fiber breakage and minimizing downtime
-
Uniform Energy Distribution — Proprietary solid-state laser cavity delivers a homogeneous beam profile across the entire spot area, eliminating hotspots for predictable tissue reaction
-
Posterior-Segment Optimized Slit Lamp — Purpose-built 10∘10^\circ stereoscopic optical head provides enhanced depth of field, high-contrast fundus illumination, and a wide peripheral view
-
Continuously Variable Spot Size — Smooth parfocal adjustment allows seamless transition from fine macular focal spots to wide panretinal photocoagulation settings
-
Vibration-Damped Ambidextrous Micromanipulator — Precision joystick-mounted micromanipulator enables effortless, micro-fine beam positioning for both left- and right-handed surgeons
-
5-Step Galilean Magnification Changer — Integrated rotary drum delivers crisp optical clarity across five magnification levels for detailed anterior and posterior segment visualization
-
Compact, Air-Cooled Solid-State Design — Quiet, energy-efficient air cooling operates on standard clinical electrical outlets without external water hookups
Clinical Applications
-
Panretinal Photocoagulation (PRP) treating proliferative diabetic retinopathy (PDR) and ischemic central or branch retinal vein occlusions
-
Focal & Grid Macular Photocoagulation sealing leaking microaneurysms in clinically significant diabetic macular edema (DME)
-
Retinal Tear & Lattice Degeneration Prophylaxis creating secure chorioretinal demarcation barriers around peripheral retinal breaks
-
Glaucoma Laser Procedures performing Argon-equivalent Laser Trabeculoplasty (ALT) and peripheral laser iridotomy for angle-closure management
Who This Is For
-
Retina Specialists and General Ophthalmologists seeking a reliable, self-contained 532 nm photocoagulation workstation without vulnerable external fiber-optic cables
-
Outpatient Laser Suites and Ambulatory Surgery Centers (ASCs) needing a compact, air-cooled green laser system with fast setup and intuitive controls
-
Comprehensive Eye Care Clinics looking for a proven, Australian-engineered Ellex Laserex platform that doubles as a high-grade diagnostic slit lamp