Description
What’s Included
- Haag-Streit Lenstar LS 900 (Gen 2) optical biometer
- Windows 10 all-in-one computer
- Keyboard and mouse
- Measurement and analysis software
- Table
- Required cables and accessories
- 1-year Digital Eye Center warranty
Condition & Warranty
Refurbished. This unit has gone through a full technical refurbishment: complete system inspection, preventive component replacement, optical, electrical and mechanical validation, and final calibration and performance testing. Covered by a 1-year warranty on parts and workmanship.
Haag-Streit Lenstar LS 900 Gen 2 — Refurbished Optical Biometer
The Haag-Streit Lenstar LS 900 is an optical biometer built around optical low-coherence reflectometry (OLCR). In one scan along the visual axis, the Lenstar LS 900 captures axial length, central corneal thickness, anterior chamber depth and lens thickness, then adds dual-zone keratometry, white-to-white and pupil diameter. That full set of anterior and axial data is what cataract surgeons need for IOL power calculation and toric planning.
This refurbished Lenstar LS 900 Gen 2 is configured as a complete station: the biometer on its table, a Windows 10 all-in-one computer with keyboard and mouse, and the measurement and analysis software, so the system is ready for IOL calculation and surgical planning once installed.
The Lenstar has a long record in the literature. A study in International Ophthalmology compared the IOLMaster 500, Lenstar LS 900 and Aladdin optical biometers for routine biometry; the National Library of Medicine indexes the full comparison.
Why Practices Choose the Haag-Streit Lenstar

- Full biometry in one capture — axial length, CCT, ACD and lens thickness are measured together along the visual axis, so the data set is consistent.
- Lens thickness measurement — useful for newer IOL formulas that use lens thickness as a predictor of effective lens position.
- Dual-zone keratometry — 32 measurement points on two concentric rings (1.65 and 2.3 mm) for reliable corneal power and astigmatism axis.
- Non-contact — no probe on the cornea, no anesthetic drops and no compression error, unlike contact A-scan.
- Automated Positioning System (APS) — the APS badge is on this unit; it helps align the measuring head with the eye for faster, repeatable captures.
- Raw data you can review — each measurement is repeated automatically, and outliers can be reviewed, excluded and recalculated.
- Integrated IOL calculation — results flow straight into the software for IOL power selection and surgical planning.
See the Haag-Streit Lenstar 900 in Action
This demo from Haag-Streit shows how a Lenstar 900 biometry measurement is taken.
Clinical Applications
- Pre-operative biometry and IOL power calculation for cataract surgery
- Toric IOL planning from keratometry and astigmatism axis data
- Refractive lens exchange and premium IOL work-ups
- Axial length follow-up in myopic eyes
- Pachymetry, anterior chamber depth and pupil measurements for anterior segment assessment
Who This Is For
- Cataract and refractive surgeons who want optical biometry in-house
- Ophthalmology practices replacing contact A-scan biometry
- Surgery centers adding a second biometer to speed up pre-op clinics
- Practices that want a refurbished Lenstar station at a fraction of new cost
Technical Specifications
| Spec | Detail |
| Manufacturer | Haag-Streit |
| Model | Lenstar LS 900 (Gen 2) |
| Technology | Optical low-coherence reflectometry (OLCR), superluminescent diode, Class 1 laser product |
| Axial length | 14 – 32 mm (display 0.01 mm) |
| Central corneal thickness | 300 – 800 µm (display 1 µm) |
| Anterior chamber depth | 1.5 – 6.5 mm (display 0.01 mm) |
| Lens thickness | 0.5 – 6.5 mm (display 0.01 mm) |
| Keratometry | Radius 5 – 10.5 mm, axis 0 – 180°; dual-zone, 32 points on two rings |
| White-to-white | 7 – 16 mm (display 0.01 mm) |
| Pupil diameter | 2 – 13 mm (display 0.01 mm) |
| Measurement modes | Phakic, aphakic, pseudophakic, silicone-filled |
| Positioning | Automated Positioning System (APS) |
| Computer | Windows 10 all-in-one with keyboard and mouse |
| Table | Included |
| Patient contact | None (non-contact) |
| Condition | Refurbished |
| Warranty | 1-year Digital Eye Center warranty |
Compare Optical Biometer Options
| Feature | Lenstar LS 900 Gen 2 (this unit) | Zeiss IOLMaster 500 Refurbished | Zeiss IOLMaster 700 Refurbished |
| Technology | Optical low-coherence reflectometry (OLCR) | Partial coherence interferometry (PCI) | Swept-source OCT |
| Axial length range | 14 – 32 mm | 14 – 38 mm | 14 – 38 mm |
| Anterior chamber depth | 1.5 – 6.5 mm | 1.5 – 6.5 mm | 0.7 – 8 mm |
| Lens thickness | 0.5 – 6.5 mm | — | 1 – 10 mm |
| Central corneal thickness | 300 – 800 µm | — | 0.2 – 1.2 mm |
| White-to-white | 7 – 16 mm | 8 – 16 mm | 8 – 16 mm |
| Condition | Refurbished | Refurbished | Refurbished |
| Price | $20,900 | $12,825 | $37,400 |
Need a longer axial length range or swept-source OCT biometry? Also consider the Zeiss IOLMaster 700 Refurbished. To complete a cataract pre-op suite with macular OCT screening, see the Zeiss Cirrus 500 Refurbished.
Questions about the Haag-Streit Lenstar LS 900? Contact us for availability and shipping details.