Haag Streit Lenstar LS-900 Optical Biometer GEN 2 – W/Electric Table, T-Cone – Used

SKU: US-BIO-HS-LEN-LS-900

US$11,000.00

Used Lenstar LS-900 Gen 2 optical biometer — OLCR 820 nm, 8 measurements in one acquisition (AL, dual-zone K, ACD, CCT, LT, WTW, pupillometry), T-Cone corneal topography included, EyeSuite IOL calculation (Barrett, Haigis, SRK/T, Holladay), electric table. 90-day warranty. Contact us.

Out of stock

Description

CURRENTLY SOLD OUTWe Can Source This For You

This exact unit sold recently — but we specialize in sourcing refurbished ophthalmic equipment. Typical turnaround is 2–4 weeks once we confirm availability with our partners. Request a free quote with no deposit required.

Request Availability → Free quote · No obligation · 90-day warranty when shipped

What’s Included

  • Haag-Streit Lenstar LS-900 Gen 2 optical biometer main unit
  • T-Cone corneal topography attachment
  • Electric ophthalmic table
  • EyeSuite IOL calculation software
  • Chinrest and headrest assembly
  • All standard cables and power supply
  • 90-day Digital Eye Center warranty on parts and workmanship

Condition & Warranty

Used. This Haag-Streit Lenstar LS-900 Gen 2 has been inspected and function-tested across all 8 biometric measurement modes, T-Cone corneal topography, and EyeSuite IOL calculation workflows. OLCR axial length reproducibility and dual-zone keratometry confirmed operational. Electric table height function verified. Covered by a 90-day warranty on parts and workmanship through Digital Eye Center.

Lenstar LS-900 — Used Haag-Streit 8-in-1 Optical Biometer with T-Cone Topography & Electric Table

The Lenstar LS-900 is Haag-Streit’s OLCR-based optical biometer — measuring all eight critical pre-surgical parameters (axial length, dual-zone keratometry, anterior chamber depth, central corneal thickness, lens thickness, white-to-white, and pupillometry scotopic and photopic) in a single 3-second non-contact acquisition without patient repositioning. This used Lenstar LS-900 Gen 2 includes the T-Cone corneal topography attachment and electric ophthalmic table, delivering a complete IOL planning workstation with corneal topography capability that practices would otherwise require two separate instruments to replicate.

Lenstar LS-900 used — Haag-Streit optical biometer Gen 2 unit front view with display
The Lenstar LS-900 uses Optical Low Coherence Reflectometry (OLCR) at 820 nm — a coherence-based measurement principle that delivers reproducibility comparable to immersion ultrasound biometry without the contact, coupling medium, or operator dependence that make immersion techniques time-consuming in busy surgical practices. Research published in International Ophthalmology (National Library of Medicine, 2015) confirmed that the Lenstar LS-900 delivers refractive outcomes equivalent to immersion ultrasound biometry — validating OLCR-based non-contact biometry as the reproducible standard for IOL power calculation in routine cataract surgery practice.

Why Practices Choose the Lenstar LS-900

Lenstar LS-900 used — OLCR optical biometry measurement in progress

  • 8 measurements in one 3-second acquisition — Axial length, dual-zone K (flat and steep), ACD, CCT, LT, WTW, and scotopic/photopic pupillometry are all captured simultaneously without patient repositioning — reducing per-eye measurement time compared to instruments that require sequential measurements or manual repositioning between parameters.
  • Dual-zone keratometry — Two concentric keratometry zones (2.3 mm and 1.65 mm) measure central and paracentral corneal curvature simultaneously, providing the multi-zone K data that Barrett Universal II, Haigis, and other modern formulas use to improve accuracy in post-refractive surgery eyes and steep/flat corneas.
  • T-Cone corneal topography — The included T-Cone Placido attachment adds full corneal topography to the biometry workflow — enabling detection of irregular astigmatism, keratoconus, and post-surgical ectasia risk in the same examination step as IOL planning.
  • EyeSuite IOL — comprehensive formula library — EyeSuite integrates Haigis, SRK/T, Hoffer Q, Holladay 1, Barrett Universal II, and other modern formulas with online formula access, enabling formula selection optimized for each eye’s biometric profile rather than defaulting to a single formula for all cases.
  • OLCR precision at 820 nm — Optical Low Coherence Reflectometry provides axial length measurements with reproducibility of ≤0.02 mm, equivalent to immersion ultrasound without requiring contact, coupling medium, or technician skill in probe placement — eliminating the primary source of operator-dependent variability in traditional biometry.
  • Electric table for ergonomic efficiency — Motorized height adjustment enables rapid patient positioning across a full day of surgical pre-op biometry without manual table adjustment, reducing staff fatigue and per-patient setup time in high-volume cataract surgery practices.
  • Connectivity and data export — EyeSuite data exports directly to surgical planning platforms and EMR systems via DICOM or direct export — eliminating manual transcription errors in IOL power and axis selection during pre-surgical planning.

Clinical Applications

Lenstar LS-900 used — EyeSuite IOL calculation software report display

  • Cataract surgery IOL power calculation — The Lenstar LS-900 provides all biometric inputs required by modern IOL formulas (AL, K, ACD, CCT, LT, WTW) in a single acquisition, enabling accurate IOL power selection for monofocal, toric, EDOF, and multifocal IOL implantation.
  • Toric IOL axis planning — Dual-zone keratometry and T-Cone topography together provide the anterior corneal astigmatism magnitude and axis data needed for toric IOL alignment marking — with the topography identifying irregular astigmatism cases where toric IOL implantation may underperform.
  • Premium IOL candidacy screening — The complete biometric profile plus corneal topography identifies candidates with irregular corneas, dry eye surface changes (reduced K reliability), or high HOAs who would not achieve the visual quality expectations that premium IOL patients demand.
  • Post-refractive surgery IOL planning — Dual-zone K and corneal topography together characterize the post-ablation corneal profile needed by dedicated post-LASIK IOL formulas (Barrett True-K, Haigis-L, ASCRS online) that require multi-zone corneal curvature data.
  • Phakic IOL sizing — Accurate ACD and WTW measurements from the Lenstar LS-900 provide the vault prediction inputs required for Visian ICL sizing, enabling phakic IOL planning without a separate measurement instrument.
  • Axial length surveillance — Serial AL measurements with OLCR reproducibility of ≤0.02 mm track myopia progression in pediatric patients and document post-surgical axial length stability in adults — applications where measurement reproducibility determines clinical utility.

Who This Is For

Lenstar LS-900 used — T-Cone corneal topography attachment and measurement system

  • High-volume cataract surgery practices — the Lenstar LS-900’s single-acquisition workflow and electric table eliminate the per-patient setup overhead in a full day of pre-surgical biometry measurements, supporting the throughput required in practices performing 500+ cases per year.
  • Premium IOL programs — practices offering EDOF, multifocal, or toric IOL implantation need the dual-zone keratometry and corneal topography that the Lenstar LS-900 with T-Cone provides, without maintaining two separate instruments for biometry and topography.
  • Practices replacing immersion ultrasound biometry — OLCR non-contact biometry eliminates the operator skill, coupling medium, and patient contact requirements of immersion techniques while delivering equivalent refractive outcomes — converting a high-skill measurement into a technician-operable workflow.
  • Surgical centers and ASCs supporting multiple surgeons — the EyeSuite formula library and data export capability enable each surgeon to use their preferred IOL formula from the same biometry dataset without requiring separate measurements on surgeon-specific instruments.
  • Practices entering refractive cataract surgery — the used Lenstar LS-900 provides the complete biometric measurement platform — OLCR biometry, dual-zone K, topography, and EyeSuite IOL calculation — required to launch a premium cataract surgery program at a fraction of the cost of a new instrument.

Technical Specifications

Specification Detail
Technology OLCR — Optical Low Coherence Reflectometry
Wavelength 820 nm
Generation Gen 2
Measurements AL, dual-zone K, ACD, CCT, LT, WTW, pupillometry (scotopic + photopic)
Acquisition Time ~3 seconds (full 8-parameter measurement)
AL Reproducibility ≤0.02 mm
Keratometry Zones Dual-zone: 2.3 mm and 1.65 mm
Topography T-Cone Placido attachment (included)
IOL Software EyeSuite (Haigis, SRK/T, Hoffer Q, Holladay 1, Barrett Universal II + more)
Table Electric ophthalmic table (included)
Manufacturer Haag-Streit AG, Switzerland
Condition Used
Warranty 90 days

Compare Optical Biometer Options

Feature Lenstar LS-900 Zeiss IOLMaster 500 Zeiss IOLMaster 5.4
Technology OLCR 820 nm PCI (Partial Coherence Interferometry) PCI (Partial Coherence Interferometry)
Keratometry Dual-zone (2.3 mm + 1.65 mm) Single-zone Single-zone
Corneal Topography Yes — T-Cone included No No
Electric Table Included Varies Varies
Condition Used Refurbished Refurbished
Price $11,000 $12,825 $7,125

Similar IOL, Biometers In Stock Now

Need a comparable iol, biometer available today? These units are in stock and ready to ship with a 90-day Digital Eye Center warranty.

Prefer to wait for the Haag Streit Lenstar LS-900 Optical Biometer GEN 2 – W/Electric Table, T-Cone – Used? Request availability and we’ll source one for you.

Questions about the Lenstar LS-900? Contact us for availability and shipping details.

Additional information

Weight 65 lbs
Dimensions 24 × 24 × 24 in
Brand

You may also like…