Lombart/ Keeler SL-B3 Slit Lamp with Optilasa R-900 Applanation Tonometer

SKU: US-SL-KEE-LOM-B3

US$4,400.00

Brand New Lombart / Keeler SL-B3 Slit Lamp — High-performance Galilean optical system, 3-step rotational magnification changer, compact tower illumination design, integrated filters, paired with an authentic Optilasa R-900 Haag-Streit style applanation tonometer. 1-year warranty.  Contact us.

What’s Included

  • Brand New Lombart / Keeler SL-B3 Slit Lamp (Tower design)

  • Brand New Optilasa R-900 Applanation Tonometer (R-type or T-type mount-ready setup)

  • Complete factory accessory kit (dust cover, spare illumination bulb, breath shield)

  • Power supply assembly and connection cables

  • 1-year warranty

Only 1 left in stock

Description

Condition & Warranty

New. This Lombart / Keeler SL-B3 Slit Lamp with Optilasa R-900 Tonometer package is brand new, factory-sealed, and supplied in its original manufacturer packaging. Unopened, unused, and pristine in every respect. Every optical element features original anti-reflective factory coatings, and all mechanical gear assemblies are factory-lubricated to exact tolerances. The integrated Optilasa R-900 applanation tonometer comes factory-calibrated. Covered by a 1-year warranty on parts and workmanship.

Lombart / Keeler SL-B3 Slit Lamp — New Workstation with Optilasa R-900 Tonometry

The Lombart SL-B3 (manufactured in partnership with Keeler) is a robust, highly reliable tower-style diagnostic slit lamp designed to bring world-class British optical clarity into everyday clinical workflows. Engineered with a premium parallel Galilean optical microscope body, the SL-B3 utilizes a fast 3-step rotational magnification drum ($10\times$, $16\times$, and $25\times$). This configuration allows eye care professionals to quickly toggle between wide-field corneal overviews and high-power structural inspections of the anterior and posterior segments.

This workstation package includes a brand-new Optilasa R-900 applanation tonometer, built on the classic Goldmann contact measurement principle. Mounting securely to the slit lamp’s illumination tower, the R-900 provides instant, precise intraocular pressure (IOP) readings during standard biomicroscopy exams. With its smooth mechanical joystick, classic Haag-Streit style tower lighting, and zero-wear brand-new factory assembly, this premium combination offers a long-term, high-tier diagnostic station for any modern eye care lane.

Research published in the National Library of Medicine confirms that Goldmann-style applanation tonometry performed on high-resolution parallel optical slit lamps remains the ultimate clinical baseline for evaluating intraocular pressure, providing unmatched accuracy across diverse corneal profiles.

Why Practices Choose the Lombart / Keeler SL-B3 & Optilasa R-900

  • Precision Galilean Optics — High-contrast parallel optical path system delivers outstanding spatial depth of field, sharp edge definition, and true-to-life color rendering

  • Integrated Optilasa R-900 Tonometer — Goldmann-style applanation tonometer mounts directly onto the tower assembly, facilitating immediate IOP measurements without moving the patient

  • 3-Step Magnification Changer — Rotational drum control provides quick, effortless switches across $10\times$, $16\times$, and $25\times$ power levels without losing focus

  • Haag-Streit Style Tower Illumination — Classic top-mounted illumination tower provides full tilting capability, essential for advanced lighting techniques like sclerotic scatter, retro-illumination, and specular reflection

  • Fluid Single-Handed Joystick — Omnidirectional joystick enables precise horizontal positioning and fluid rotational height adjustments for quick patient alignment

  • Integrated Diagnostic Filter Suite — Features instantly switchable Cobalt Blue, Red-Free (Green), Neutral Density, and Heat-Absorbing optical filters

  • Zero-Wear Factory Reliability — Brand-new manufacturing ensures optimal optical alignment, pristine internal glass surfaces, and maximum working life for busy practices

Clinical Applications

  • Comprehensive Anterior Segment Examinations inspecting corneal foreign bodies, abrasions, dry eye indicators, and pre/post-op cataract developments

  • Goldmann-Standard Applanation Tonometry obtaining precise intraocular pressure metrics to establish or monitor active glaucoma management plans

  • Fluorescein Contact Lens Evaluations utilizing the high-contrast cobalt blue illumination filter to inspect soft and rigid gas permeable (RGP) lens alignment and tears

  • Posterior Pole Biomicroscopy pairing the high-transmission optical paths with specialized handheld auxiliary lenses (such as a 90D or 78D) for vitreous and macular reviews

Who This Is For

  • Optometrists and General Ophthalmologists outfitting a new clinic or lane with factory-fresh, gold-standard diagnostic equipment

  • High-Volume Practices seeking a zero-wear, durable tower slit lamp built for complete long-term reliability without maintenance overhead

  • Surgical and Diagnostic Centers requiring factory-sealed precision instruments backed by full 1-year coverage

Technical Specifications

Specification Detail
Model Lombart / Keeler SL-B3 w/ Optilasa R-900
Type Tower Illumination (Haag-Streit Style) Galilean Slit Lamp
Magnification Steps 3-Step Rotary Drum Changer ($10\times$, $16\times$, $25\times$)
Eyepieces $12.5\times$ focusing eyepieces
Slit Width / Length Continuous adjustment up to 14 mm
Filters Cobalt Blue, Red-Free, Neutral Density, Heat-Absorbing
Tonometer Model Optilasa R-900 (Goldmann-style Applanation)
Pressure Range 0 to 80 mmHg
Condition New
Warranty 1-year warranty on parts and workmanship