Description
What’s Included
- Zeiss Humphrey Field Analyzer 3 (HFA3) 860
- Electric table
- Trial lens
- Keyboard
- Patient response button (clicker)
- Dust cover
- Power cable
- 90-day Digital Eye Center warranty
Condition & Warranty
Used. This unit has been tested, is in excellent working order and has been cleaned; it is ready to use once received. It shows some signs of usage, documented in the product photos. Covered by a 90-day warranty on parts and workmanship.
Zeiss Humphrey HFA3 860 Visual Field Analyzer — Used with Electric Table
The Zeiss Humphrey Field Analyzer 3 Model 860 is the top tier of the HFA3 line. Every HFA3 model shares the SITA threshold strategies, the 24-2, 30-2, 10-2 and 60-4 patterns and the Esterman tests; the hfa3 860 adds SITA-SWAP blue-on-yellow perimetry, kinetic testing, vertex monitoring, the RelEYE monitor and the automated Liquid Trial Lens. This used hfa3 860 ships on its electric table with keyboard, patient response button, trial lens and dust cover, so it arrives as a complete perimetry station.
The Humphrey SITA family is one of the most studied threshold algorithms in glaucoma care. A multicenter study indexed by the National Library of Medicine (American Journal of Ophthalmology, 2019) describes how SITA strategies are constructed and validated against standard threshold testing on the Humphrey platform.
Why Practices Choose the Zeiss Humphrey HFA3 860

- Full HFA3 test library — 24-2, 30-2, 10-2, 60-4, Nasal step and Macula threshold patterns plus suprathreshold screening.
- SITA-SWAP — blue-on-yellow perimetry, available only on the 850/860 tier.
- Kinetic and custom kinetic testing — peripheral isopter mapping for neuro-ophthalmic cases.
- Automated Liquid Trial Lens — the 860 sets the patient’s correction automatically, reducing manual lens handling between tests.
- Guided Progression Analysis (GPA) — flags statistically significant change from baseline across a patient’s SITA history.
- Esterman and disability tests — monocular and binocular Esterman plus Social Security Disability protocols.
- Electric table included — height-adjustable patient positioning out of the box.
See the Zeiss Humphrey HFA3 860 in Action
This demo from ZEISS walks through the Humphrey Field Analyzer 3 platform, its SITA test workflow and the on-screen review of visual field results.
Clinical Applications
- Glaucoma diagnosis and monitoring — SITA 24-2 and 30-2 threshold testing with GPA progression analysis.
- Central and macular field testing — 10-2 and Macula patterns for paracentral defects and drug-toxicity screening.
- Neuro-ophthalmology — 60-4 peripheral and kinetic testing for chiasmal, stroke and optic-nerve field loss.
- Driver and disability evaluations — Esterman binocular and Social Security Disability protocols.
- Early functional loss — SITA-SWAP blue-on-yellow perimetry.
Who This Is For
- Glaucoma practices that want the full HFA3 feature set, including SWAP and kinetic testing.
- Neuro-ophthalmology and multispecialty groups that rely on peripheral and kinetic field mapping.
- Practices performing driver-license and disability field documentation.
- Clinics upgrading from an HFA II-i that want GPA continuity on the current Humphrey platform.
Technical Specifications
| Specification | Detail |
| Manufacturer | Carl Zeiss Meditec (Humphrey) |
| Model | Humphrey Field Analyzer 3 (HFA3) Model 860 |
| Type | Automated static and kinetic perimeter (visual field analyzer) |
| Threshold test library | 24-2, 30-2, 10-2, 60-4, Nasal step, Macula |
| Threshold strategies | SITA Standard, SITA Fast, Full Threshold, SITA-SWAP (blue-on-yellow) |
| Suprathreshold screening | C40, C64, C76, C80, Armaly, peripheral screening patterns |
| Specialty tests | Esterman monocular and binocular, Social Security Disability (monocular, binocular) |
| Kinetic testing | Standard and custom kinetic (850/860 tier) |
| 860-tier features | Automated Liquid Trial Lens, vertex monitoring, RelEYE monitor |
| Analysis | Guided Progression Analysis (GPA), STATPAC single-field analysis |
| Maximum temporal range | 90° |
| Stimulus duration | 200 ms |
| Testing distance | 30 cm |
| Bowl illumination | 31.5 ASB |
| Included table | Electric table |
| Condition | Used — tested, cleaned, some signs of usage |
| Warranty | 90-day Digital Eye Center warranty on parts and workmanship |
Compare Humphrey Visual Field Analyzer Options
| Feature | HFA3 860 w/ Electric Table (this unit) | HFA II-i 745i Factory USB | HFA II-i 740i Gen USB | HFA II-i 740i Floppy |
| Platform | HFA3 (current generation) | HFA II-i | HFA II-i | HFA II-i |
| SITA Standard / SITA Fast | Yes | Yes | Yes | Yes |
| SITA-SWAP (blue-on-yellow) | Yes | No | No | No |
| Kinetic testing | Yes | — | — | — |
| Liquid Trial Lens | Yes | No | No | No |
| Data transfer | USB / network | Factory USB | Generic USB | Floppy disk |
| Electric table | Included | — | — | — |
| Condition | Used | Refurbished | Refurbished | Refurbished |
| Warranty | 90 days | 6 months | 6 months | 6 months |
| Price | $19,800 | $8,075 | $7,600 | $7,125 |
On a tighter budget? The Oculus Easyfield C visual field tester is a compact central-field perimeter that runs in normal room lighting.
Questions about the Zeiss Humphrey HFA3 860? Contact us for availability and shipping details.