Description
What’s Included
- Zeiss Humphrey HFA II 740i visual field analyzer
- Software version 5.0 with GPA and HFA NET licenses
- Generic USB connectivity
- Patient response button
- Keyboard and mouse
- Printer
- Electric table
- Manual on USB drive
- Cables and accessories
- 1-year Digital Eye Center warranty
Condition & Warranty
Refurbished. This Humphrey 740i has been professionally refurbished, then fully calibrated and tested so it is fully functional before shipment. Covered by a 1-year warranty on parts and workmanship.
Humphrey Field Analyzer 740i — Refurbished Visual Field Analyzer with USB and Printer
The Humphrey Field Analyzer 740i is the threshold model of the Zeiss HFA II-i series, the automated perimeter that set the reference standard for glaucoma visual field testing. This refurbished Humphrey Field Analyzer 740i runs software version 5.0 with SITA Standard and SITA Fast threshold testing, STATPAC analysis and a Guided Progression Analysis (GPA) license, and it monitors fixation with Gaze Tracking and a video eye monitor. A generic USB port handles data export, the HFA NET license is enabled, and a printer is included, so the Humphrey Field Analyzer 740i arrives on its electric table as a complete visual field station for glaucoma, neuro-ophthalmic and functional field testing.
Research in the National Library of Medicine (American Journal of Ophthalmology, 2022) examined standard reliability indices together with gaze tracking metrics in glaucoma and glaucoma suspects, showing why continuous fixation records like the ones the 740i prints alongside each field matter when judging whether a visual field result can be trusted.
Why Practices Choose the Humphrey Field Analyzer 740i

- SITA Standard and SITA Fast — Zeiss SITA strategies deliver threshold fields in about half the time of conventional algorithms; Full Threshold and FastPac remain available when a protocol calls for them
- Guided Progression Analysis included — the GPA license compares follow-up fields against baseline tests to help document glaucoma progression over time
- Gaze Tracking on every test — unlike the entry-level 720i, the 740i includes Zeiss Gaze Tracking, which uses real-time image analysis to confirm the patient is looking at the fixation target; the gaze track graph prints with the results as a fixation record
- Three layers of fixation control — Gaze Tracking works together with the video eye monitor and Heijl-Krakau blind spot monitoring, helping technicians catch unreliable responses during the test instead of after it
- STATPAC analysis at the instrument — Single Field Analysis with global indices, the Glaucoma Hemifield Test and Change Analysis across serial tests support glaucoma diagnosis and follow-up
- USB export and HFA NET — export patient data over USB instead of floppy disks, with the HFA NET license enabled for network connectivity
- Custom test patterns — the 740i lets you create and store your own test patterns alongside the standard 24-2, 30-2, 10-2 and peripheral libraries
- Touch screen operation — menu and icon commands on the touch screen, plus the included keyboard and mouse, keep training simple for new perimetry technicians
See the Humphrey Field Analyzer 740i in Action
An independent hands-on walkthrough of the Zeiss Humphrey HFA II-i 740i/750i visual field analyzer and its testing workflow.
Clinical Applications
- Glaucoma diagnosis and staging — SITA Standard 24-2 and 30-2 threshold testing with STATPAC Single Field Analysis and the Glaucoma Hemifield Test
- Glaucoma progression monitoring — serial threshold fields reviewed with Guided Progression Analysis and STATPAC Change Analysis to document stability or progression
- Central field mapping — the 10-2 pattern for advanced glaucoma and for macular and central field concerns
- Neuro-ophthalmology — 24-2 and 30-2 fields to characterize hemianopic, quadrantanopic and other visual pathway defects
- Functional field assessment — Esterman monocular and binocular tests for driving and disability evaluations
Who This Is For
- Ophthalmology and optometry practices adding automated perimetry — a complete Humphrey station with electric table and printer for glaucoma care
- Practices moving off floppy-disk perimeters — USB export simplifies data handling compared with floppy-based HFA II units
- High-volume glaucoma practices — a second visual field lane that runs the same SITA protocols and GPA follow-up as an existing Humphrey
- Practices that need fixation documentation — Gaze Tracking printouts support reliability review on every field
Technical Specifications
| Specification | Detail |
| Instrument | Zeiss Humphrey Field Analyzer HFA II-i 740i |
| Type | Automated static perimeter (visual field analyzer) |
| Software | Version 5.0 |
| Licenses | GPA (Guided Progression Analysis), HFA NET |
| Threshold strategies | SITA Standard, SITA Fast, Full Threshold, FastPac |
| Test patterns | 24-2, 30-2, 10-2, Macula, 60-4, Nasal Step, Esterman monocular and binocular, custom patterns |
| Fixation monitoring | Gaze Tracking, video eye monitor, Heijl-Krakau blind spot monitoring |
| Maximum stimulus | 10,000 asb |
| Background illumination | 31.5 asb |
| Statistical analysis | STATPAC (Single Field Analysis, Glaucoma Hemifield Test, Change Analysis), GPA |
| Interface | Touch screen, keyboard and mouse |
| Connectivity | Generic USB, HFA NET license |
| Printer | Included |
| Table | Electric table, included |
| Condition | Refurbished, fully calibrated and tested |
| Warranty | 1-year Digital Eye Center warranty on parts and workmanship |
Compare Humphrey HFA II-i Visual Field Analyzers
| Feature | Humphrey 740i Gen USB (this unit) | Humphrey 740i Floppy | Humphrey 745i Factory USB | Humphrey HFA II 750i v5.1.3 |
| Platform | HFA II-i 740i | HFA II-i 740i | HFA II-i 745i | HFA II-i 750i |
| Software and licenses | Version 5.0 with GPA and HFA NET | Not stated | Not stated | Version 5.1.3 with GPA and HFA NET |
| Threshold strategies | SITA Standard, SITA Fast, Full Threshold, FastPac | Full Threshold, FastPac | SITA Standard, SITA Fast, Full Threshold | SITA Standard, SITA Fast, Full Threshold, FastPac |
| Gaze tracking | Yes | Yes | Yes | Yes, plus head tracking |
| Data export | Generic USB | Floppy disk | Factory USB | Factory USB, HFA NET |
| Printer | Yes | Yes | Yes | Yes |
| Electric table | Included | Included | Included | Included |
| Condition | Refurbished | Refurbished | Refurbished | Refurbished |
| Warranty | 1-year | 6-month | 6-month | 1-year |
| Price | $7,125 | $7,125 | $8,075 | $8,550 |
Need more testing options? The Zeiss Humphrey Field Analyzer 3 (HFA3) 860 moves up to the newer HFA3 platform, while the Zeiss Humphrey Matrix 800 offers frequency doubling technology in a compact unit.
Questions about the Humphrey Field Analyzer 740i? Contact us for availability and shipping details.