Accutome PachPen 24-5100 Pachymeter w/ Case – Used

SKU: US-PAC-ACC-PCP-24-5100

US$1,650.00

Used Accutome PachPen 24-5100 Handheld Ultrasonic Pachymeter with carrying case — ±5 µm clinical accuracy, 65 MHz probe, 300–999 µm range, ~15,000-reading lithium battery. 90-day warranty. Contact us.

Only 1 left in stock

Description

What’s Included

  • Accutome PachPen 24-5100 handheld ultrasonic pachymeter (as photographed)
  • Carrying case (per listing title)
  • 90-day Digital Eye Center warranty

Per Eyes Equipment standard listing terms: “If a specific accessory is not shown in the pictures, it’s not included.” Replacement probe, lithium battery (beyond what is installed), training media, or operating instructions are NOT included unless visible in the product photos. Contact us before purchase if you need specific accessories.

Condition & Warranty

Used. Tested before listing, ready to use once received. Item has been cleaned. Some signs of usage may be visible in the product photos. Probe verified functional, measurement output confirmed, battery confirmed holding charge. Covered by a 90-day warranty on parts and workmanship.

Accutome PachPen — Used Handheld Ultrasonic Pachymeter

Accutome PachPen 24-5100 pachymeter used — front view with caseThe Accutome PachPen 24-5100 is a handheld ultrasonic pachymeter that captures central corneal thickness (CCT) in seconds, used in LASIK candidate evaluation, keratoconus screening, and corrected IOP measurement for glaucoma. This used accutome pachpen ships inspected with a 90-day warranty and a hard carrying case, ready for chairside use.

The PachPen uses a 65 MHz sampling probe with Digital Signal Analysis to filter out non-perpendicular reads, delivering measurements in the 300–999 µm range with ±5 µm clinical accuracy and ±1 µm electronic resolution at 1640 m/sec. The unit weighs 3 oz and runs on a long-life lithium battery good for approximately 15,000 readings — typical mainframe lifetime for a busy practice.

Per a National Library of Medicine-indexed study (Int Ophthalmol, 2015), the Accutome PachPen demonstrated strong intraobserver repeatability and interobserver reproducibility across personnel of varying training grades — supporting its use across optometric, technician, and ophthalmologist hands without significant drift.

Why Practices Choose the PachPen

  • Accutome PachPen — display screen with corneal thickness reading±5 µm clinical accuracy — meets the precision requirements for refractive surgery candidate evaluation and serial keratoconus monitoring.
  • Digital Signal Analysis — eliminates non-perpendicular reads automatically, so the displayed value is a clean perpendicular measurement rather than an averaged-with-noise estimate.
  • 15,000-reading battery life — long-life lithium pack means the device essentially never runs out between routine charges.
  • 2.5 mm probe tip + 65 MHz sampling — precise corneal apex contact, no fluid bridge required, no slit-lamp setup needed.
  • 3 oz handheld form factor — sits in a coat pocket or chair-side tray; reaches the patient regardless of position.
  • Wide measurement range 300–999 µm — covers normal corneas through edema and post-graft thickness without scale switches.
  • Reproducible across operators — published reproducibility data supports use by technicians without concern for measurement drift between examiners.

Clinical Applications

  • LASIK and refractive surgery candidate evaluation — confirming residual stromal bed planning
  • Keratoconus screening and longitudinal monitoring
  • Glaucoma assessment — corrected IOP based on Goldmann correction tables
  • Corneal edema evaluation in Fuchs dystrophy and post-cataract patients
  • Pre-operative cataract surgery planning when corneal disease is suspected
  • Corneal graft monitoring following PKP or DSAEK

Who This Is For

  • Refractive surgery practices — primary or backup PachPen for LASIK consults
  • Optometric practices doing keratoconus screening or corrected-IOP glaucoma management
  • Glaucoma specialists who want corrected IOP for thicker/thinner corneas
  • Optometric and ophthalmic teaching programs needing a reproducible portable pachymeter
  • Mobile clinics adding corneal thickness capture without slit-lamp infrastructure

Technical Specifications

Spec Detail
Type Handheld ultrasonic pachymeter
Measurement range 300–999 µm
Clinical accuracy (1σ) ±5 µm
Electronic resolution (@1640 m/sec) ±1 µm
Probe sampling 65 MHz
Probe tip diameter 2.5 mm
Signal processing Digital Signal Analysis (rejects non-perpendicular reads)
Battery Long-life lithium — ~15,000 readings
Weight 3 oz (85 g)
Condition Used — inspected, probe and battery verified
Warranty 90 days (parts and workmanship)

Compare Pachymeter / Corneal-Thickness Options

Feature Accutome PachPen 24-5100 (this listing) Reichert iPac Pachymeter
Method Handheld ultrasonic Handheld ultrasonic
Probe sampling 65 MHz, 2.5 mm tip Reichert ultrasonic
Range 300–999 µm Standard CCT range
Clinical accuracy ±5 µm (1σ) ±5 µm class
Battery Long-life lithium (~15K reads) Rechargeable + cradle
Includes charging cradle No (lithium battery) Yes
Best for LASIK/keratoconus workhorse Reichert ecosystem with cradle
Condition / Warranty Used / 90 days Used / 90 days
Price $1,650 $1,980

Want a Reichert pachymeter with a charging cradle instead of a long-life lithium battery? See the Reichert iPac Pachymeter with charging cradle.

Questions about the Accutome PachPen? Contact us for probe condition, battery age, and freight quote — call 305-771-4562 or use the contact form.

Additional information

Weight 3 lbs
Dimensions 10 × 10 × 10 in