Description
What’s Included
- Zeiss Humphrey HFA II-i 750i visual field analyzer
- USB connectivity (Gen USB upgrade)
- Integrated printer
- Patient response button
- Power cables and accessories
- 6-month Digital Eye Center warranty
Condition & Warranty
Refurbished. This Zeiss Humphrey 750i visual field analyzer has been fully inspected, tested, and verified for accurate SITA perimetry function, USB data transfer, and integrated printer operation. Carefully calibrated and cleaned before shipping. Covered by a 6-month warranty on parts and workmanship.
Humphrey 750i Visual Field Analyzer — Refurbished Automated Perimeter

Research published in Eye identifies the Humphrey Field Analyzer with SITA Standard automated perimetry as the reference standard for glaucoma visual field testing — the clinical benchmark against which newer portable and remote perimetry devices are compared in case-finding studies worldwide.
Why Practices Choose the Humphrey 750i Visual Field Analyzer
- SITA Standard, SITA Fast, and SITA SWAP — all three algorithms included — SITA Standard delivers the gold-standard threshold estimate for glaucoma monitoring; SITA Fast cuts testing time approximately in half for patients with poor fixation or fatigue; SITA SWAP enables blue-on-yellow short-wavelength perimetry for detection of early glaucomatous loss before conventional white-on-white perimetry detects it
- Full clinical test pattern library — 24-2 central field for glaucoma staging and follow-up; 30-2 extended central field; 10-2 central 10° testing for advanced glaucoma and macular disease; 60-4 for peripheral field screening; Esterman binocular functional field for driving fitness and disability assessment; Central 40 and screening patterns also available
- USB connectivity (Gen USB) — direct EMR and FORUM integration — the Gen USB upgrade provides native USB data export from the 750i; test data transfers directly to Zeiss FORUM Glaucoma Workplace, EMR systems, and other VF management platforms without floppy disk or manual data entry
- Integrated printer — immediate hard-copy output — onboard printer produces the standard Humphrey single-field analysis, GHT, and STATPAC printouts at the instrument without a separate print station; important for paper-based workflows and patient file documentation
- STATPAC statistical analysis — STATPAC compares each result to a normative age-corrected database; GHT (Glaucoma Hemifield Test) and Mean Deviation, Pattern Standard Deviation, and Visual Field Index outputs are standard on the 750i for glaucoma staging and progression monitoring
- Goldmann stimulus sizes I–V — full protocol flexibility — standard Goldmann size III for routine perimetry; larger stimuli (IV and V) for advanced loss testing; size I for selective early loss detection; all five sizes selectable for specialized clinical and research protocols
- Background illumination 31.5 ASB — standardized photopic testing — the Humphrey bowl maintains 31.5 apostilbs background illumination to the HFA standard, ensuring results are comparable across instruments and clinical sites for multi-site practices and research protocols
Clinical Applications
- Glaucoma visual field testing — primary use — SITA Standard 24-2 is the clinical standard for glaucoma staging and follow-up; the 750i runs full SITA test batteries for newly diagnosed and established glaucoma patients; STATPAC VFI trend analysis supports progression detection over serial testing
- Glaucoma suspect monitoring — early glaucoma suspects with elevated IOP, suspicious disc, or OCT RNFL loss are monitored with serial 24-2 SITA Standard; the 750i provides the baseline and follow-up testing required for conversion detection before structural damage progresses
- Neuro-ophthalmology — visual pathway field defects — 24-2 and 30-2 SITA Standard testing characterizes hemianopias, quadrantanopias, and other neuro-related field defects for chiasmal and retrochiasmal pathway lesions; 10-2 testing maps central scotomas in optic neuritis and other anterior pathway conditions
- Advanced glaucoma — 10-2 testing — patients with severe glaucoma and field loss threatening fixation are tested with the 10-2 pattern to map remaining central field with higher spatial resolution; the 750i runs 10-2 SITA Fast and Standard for advanced glaucoma monitoring
- Functional field testing — Esterman binocular — the Esterman binocular field test assesses functional visual field for driving fitness, occupational requirements, and disability evaluation; the 750i runs Esterman binocular testing as part of its standard pattern library
- Macular disease visual field correlation — 10-2 SITA testing at the 750i characterizes central scotomas in age-related macular degeneration, macular dystrophies, and drug toxicity (hydroxychloroquine screening) where central field is the primary concern
Who This Is For
- Glaucoma-focused ophthalmology and optometry practices — the Humphrey 750i is the standard automated perimeter for glaucoma testing workflows; SITA Standard, STATPAC, and GHT outputs are the basis for glaucoma staging, treatment decisions, and progression monitoring in high-volume glaucoma practices
- Optometry practices adding visual field testing — the refurbished 750i at $8,075 delivers full Humphrey automated perimetry capability without new-instrument cost; 6-month warranty included; USB connectivity ensures compatibility with existing EMR infrastructure
- Multi-site practices and ASCs standardizing on Humphrey — the HFA II-i 750i produces STATPAC outputs that compare directly across sessions and sites; practices using FORUM Glaucoma Workplace benefit from USB data transfer for centralized result management
- Neuro-ophthalmology practices — the 750i’s 24-2, 30-2, and 10-2 SITA test battery is the standard tool for characterizing visual pathway defects and monitoring neuro-ophthalmological conditions requiring serial visual field assessment
Technical Specifications
| Specification | Detail |
| Instrument | Zeiss Humphrey HFA II-i 750i Visual Field Analyzer |
| Test Strategies | SITA Standard, SITA Fast, SITA SWAP, Full Threshold |
| Test Patterns | 24-2, 30-2, 10-2, 60-4, Esterman (binocular), Central 40, and others |
| Stimulus Sizes | Goldmann I, II, III, IV, V |
| Background Illumination | 31.5 ASB (apostilbs) |
| Stimulus Duration | 200 ms |
| Maximum Temporal Range | 89° |
| Statistical Analysis | STATPAC (MD, PSD, VFI, GHT) |
| Connectivity | USB (Gen USB upgrade) |
| Printer | Integrated |
| Condition | Refurbished |
| Warranty | 6 months |
Compare Humphrey Visual Field Analyzer Options
| Model | Connectivity | Condition | Price |
| HFA 745i Gen USB | USB | Refurbished | $8,075 |
| HFA 750i Gen USB + Printer (this unit) | USB + integrated printer | Refurbished | $8,075 |
| HFA 750i Floppy + Printer | Floppy disk | Refurbished | $7,600 |
| HFA 750i Standard | Standard | Refurbished | $7,600 |
Questions about the Humphrey 750i Visual Field Analyzer? Contact us — we can confirm USB port function, printer operation, and FORUM compatibility before purchase.
