Medtronic Solan XL Applanation Tonometer / Tono-Pen with Case – Used

SKU: US-TON-MED-XL

US$1,540.00

Used Medtronic Solan XL applanation tonometer / Tono-Pen with carrying case — Tono-Pen XL platform, 5–80 mmHg, gravity-independent, 2.1 oz handheld. Goldmann-correlated. Visible signs of usage disclosed. 90-day warranty. Contact us.

Only 1 left in stock

Description

What’s Included

  • Medtronic Solan XL applanation tonometer / Tono-Pen handheld unit (as photographed)
  • Carrying case (per listing title)
  • 90-day Digital Eye Center warranty

Per Eyes Equipment standard listing terms: “Everything shown with the unit comes with it” — refer to the product photos for the exact configuration. Replacement Ocu-Cel XL batteries, Ocu-Film+ tip covers, calibration check disc, or operating manual are NOT included unless visible in the product photos. Contact us before purchase if you need specific accessories.

Condition & Warranty

Used. Tested in excellent working order, ready to use once received — no additional steps needed. Item has been cleaned. The unit has visible signs of usage — please review the product photos for cosmetic detail before purchase. IOP measurement function and the LCD readout confirmed operational. Covered by a 90-day warranty on parts and workmanship.

Medtronic Solan XL — Used Handheld Applanation Tonometer

Medtronic Solan XL Tono-Pen used — front view with caseThe Medtronic Solan XL is the original Solan-branded version of the Tono-Pen XL handheld applanation tonometer — same hardware platform that Reichert later acquired and continued to manufacture. This used medtronic solan xl ships in its carrying case with a 90-day DEC warranty, providing a budget-friendly entry point into Goldmann-correlated handheld IOP measurement.

The Solan XL reads IOP from 5 to 80 mmHg using a micro strain gauge transducer, runs on 2 Ocu-Cel XL batteries, and weighs only 2.1 oz (61 g) — small enough to live in a coat pocket and reach the patient regardless of position. Unlike rebound or air-puff devices, the Solan XL works with the patient sitting, standing, or lying down — gravity-independent design that’s critical for bedside, emergency, and pediatric exams.

Per a National Library of Medicine-indexed study (Middle East African J Ophthalmol, 2018), the Tono-Pen XL platform showed clinically meaningful correlation with Goldmann applanation tonometry in both normal controls and glaucoma patients — supporting its role as a reliable handheld alternative when Goldmann isn’t practical.

Why Practices Choose the Solan XL

  • Medtronic Solan XL Tono-Pen — display screen detailGoldmann-correlated readings — micro strain gauge tonometry validated against the slit-lamp-mounted reference standard.
  • 5–80 mmHg measurement range — covers normotensive through severe glaucomatous IOP without dial switching.
  • Position-independent — works with patient sitting, standing, or lying down. Critical for bedside hospital rounds and emergency settings.
  • 2.1 oz handheld form factor — pocketable and patient-friendly. Reaches restricted patients (wheelchair, supine, sedated) without slit-lamp setup.
  • 2 Ocu-Cel XL batteries — long battery life with widely-available cells; no proprietary charging dock required.
  • Same hardware as Reichert Tono-Pen XL — Solan was Medtronic’s branding for the platform; Reichert later acquired the line. Service economics carry over.
  • Disposable Ocu-Film+ tip covers — minimizes cross-contamination between patients (purchase separately as consumables).

Clinical Applications

  • Routine glaucoma screening in optometric and general ophthalmology practice
  • Pediatric IOP measurement when slit-lamp positioning isn’t possible
  • Bedside / inpatient IOP monitoring on hospital rounds
  • Emergency department and trauma setting IOP capture
  • Pre- and post-op IOP checks in cataract and refractive surgery
  • Mobile and outreach screening clinics

Who This Is For

  • Optometric practices needing a budget-friendly handheld tonometer for backup or secondary lane
  • Pediatric ophthalmology practices needing IOP capture on uncooperative patients
  • Emergency departments and inpatient ophthalmology consult services
  • Veterinary clinicians who want a human-grade Tono-Pen XL for primate / large animal practice
  • Optometry schools and residency programs needing a clinical workhorse for training

Technical Specifications

Spec Detail
Type Handheld applanation tonometer (Tono-Pen XL platform)
Brand at time of manufacture Medtronic Solan (later acquired by Reichert)
Measurement range 5–80 mmHg
Transducer Micro strain gauge
Power source 2 × Ocu-Cel XL batteries
Position Gravity-independent — works in any patient position
Tip covers Ocu-Film+ disposable (purchase consumables separately)
Weight 2.1 oz (61 g)
Goldmann correlation Clinically validated (per indexed studies)
Condition Used — visible signs of usage; tested operational
Warranty 90 days (parts and workmanship)

Compare Handheld Tonometer Options

Feature Medtronic Solan XL (this listing) Tono-Pen XL Medtronic Refurb Tono-Pen XL Reichert Refurb Reichert Avia Tono-Pen
Generation 1st gen (Solan / XL) 1st gen (Medtronic XL) 1st gen (Reichert XL) 2nd gen (Avia)
Range 5–80 mmHg 5–55 mmHg 5–55 mmHg 5–55 mmHg
Measurement mode 5-tap standard 5-tap standard 5-tap standard 2-tap Quick-Tap
Battery 2 × Ocu-Cel XL 9V cell 9V cell POWERCEL pack
Best for Lowest-cost handheld entry Refurb backup option Refurb / training Modern high-volume clinic
Condition / Warranty Used / 90 days Refurbished / 6 months Refurbished / 6 months Used / 90 days
Price $1,540 $2,695 $2,895 $3,300

Want a Tono-Pen XL with a 6-month refurbished warranty instead of 90-day Used? Compare with the refurbished Tono-Pen XL Medtronic. Need the modern 2-tap Quick-Tap version? See the Reichert Avia Tono-Pen.

Questions about the Medtronic Solan XL? Contact us for battery condition, tip cover supply, or freight quote — call 305-771-4562 or use the contact form.

You may also like…