Topcon Aladdin-M Biometer – Topographer System

SKU: BIO-TOP-ALA-M

US$16,500.00

Brand new Topcon Aladdin-M — integrated PCI optical biometry and Hartmann-Shack corneal topography in a single platform. AL, K, ACD, WTW, toric IOL planning, Barrett Universal II. 1-year manufacturer warranty. Contact us.

Only 1 left in stock

Description

What’s Included

  • Topcon Aladdin-M main unit (brand new)
  • Patient chin and head rest assembly
  • Integrated software with IOL calculator and toric planner
  • Monitor, keyboard, and accessories
  • Power and data cables
  • 1-year manufacturer warranty

Condition & Warranty

Brand new. Ships factory-fresh directly from Topcon distribution — never used, in original packaging. Covered by a 1-year manufacturer warranty on parts and workmanship with full Topcon technical support.

Topcon Aladdin-M — Brand New Integrated Biometer and Corneal Topographer

Topcon Aladdin-M brand new integrated biometer topographer — front view The Topcon Aladdin-M is an all-in-one pre-surgical platform combining optical biometry and Hartmann-Shack corneal topography in a single compact instrument — eliminating the need for separate devices at the cataract lane. Brand new and shipping directly from Topcon distribution, the Topcon Aladdin captures axial length, keratometry, ACD, WTW, and full anterior topography in a single patient exam, with integrated Barrett Universal II, Haigis, Holladay 2, and SRK/T formula support for premium IOL planning. DICOM and HL7 connectivity enables direct integration with compatible EMR systems and surgical planning platforms.

Published research in the National Library of Medicine confirms that modern optical biometry combined with the Barrett Universal II formula delivers superior refractive predictability compared to older biometry platforms and single-variable formulas — making precise biometry the foundation of premium cataract outcomes.

Why Practices Choose the Topcon Aladdin-M

  • Topcon Aladdin-M toric IOL planning software screen — Barrett formulaIntegrated biometry + topography — PCI-class axial length measurement and Hartmann-Shack corneal topography in one instrument; eliminates the cost and workflow friction of maintaining two separate devices.
  • Hartmann-Shack wavefront topography — Full anterior corneal surface mapping for toric IOL axis planning, multifocal IOL candidacy screening, and irregular astigmatism assessment.
  • Barrett Universal II built in — The highest-accuracy modern IOL formula integrated natively alongside Haigis, Holladay 2, and SRK/T; no external calculator required.
  • Comprehensive single-capture measurements — AL, keratometry (flat and steep axis), ACD, WTW, pupil diameter, and topography all captured in one efficient exam.
  • Toric IOL planning module — Integrated axis marking and surgical planning; supports direct toric calculator workflows without a separate software step.
  • DICOM and HL7 connectivity — Integrates with EMR systems and surgical planning platforms; data exports directly to compatible surgical systems.
  • Brand new with full warranty — Ships factory-fresh from Topcon distribution; covered by a 1-year manufacturer warranty with full technical support.

Clinical Applications

  • Cataract pre-surgical biometry — Complete AL, K, and ACD measurement set for accurate IOL power calculation using modern formulas.
  • Toric IOL planning — Anterior topography identifies the steep meridian and total corneal astigmatism for precise toric alignment and power selection.
  • Premium IOL candidacy screening — Topography maps identify irregular astigmatism, keratoconus risk, and prior refractive surgery that affect multifocal or EDOF lens selection.
  • Post-refractive cataract planning — Topography-assisted formulas (Barrett True-K, Haigis-L) improve IOL accuracy in LASIK/PRK/RK eyes.
  • High-volume pre-op lane efficiency — Single capture replaces biometer + topographer workflow, reducing exam time and equipment footprint per lane.

Who This Is For

  • Cataract surgeons implanting toric or premium IOLs — corneal topography is essential for premium lens planning; having it integrated with biometry eliminates a workflow step.
  • High-volume surgery centers — combined biometry + topography in one instrument reduces lane equipment, service contracts, and technician training requirements.
  • Practices upgrading from older biometers — replaces aging IOLMaster 500 or ultrasound biometers with a brand-new integrated system supporting modern formulas.
  • Practices adding topography for the first time — the Topcon Aladdin-M delivers both biometry and topography in one capital purchase instead of two.
  • Refractive-cataract practices — topography + modern formula integration supports the outcomes-focused workflows that premium cataract patients expect.

Technical Specifications

Spec Detail
Manufacturer Topcon
Model Aladdin-M
Biometry technology Optical Low Coherence Reflectometry (OLCR / PCI)
Topography technology Hartmann-Shack wavefront-based anterior topography
Measurements AL, K (flat/steep), ACD, WTW, pupil diameter, corneal topography
IOL formulas Barrett Universal II, Haigis, Holladay 2, SRK/T, and more
Toric planning Integrated toric IOL calculator with axis marking
Connectivity DICOM, HL7, LAN
Display Touchscreen interface
Condition Brand new
Warranty 1 year — manufacturer

Compare IOL Biometry Systems

System Technology Topography Barrett Condition Price
IOLMaster 700 SS-OCT Yes Yes Refurbished $37,500
Aladdin-M (this unit) PCI + Topo Yes Yes Brand new $16,500
IOLMaster 500 PCI No Yes Refurbished $12,825
IOLMaster 5.4 PCI No No Refurbished $7,125

Questions about the Topcon Aladdin-M? Contact us — we will provide software details, availability, and financing options.

Additional information

Weight 65 lbs
Dimensions 24 × 24 × 24 in
Brand

You may also like…