Zeiss IOL Master Version 500 Optical Biometer w/ Electric Table – Used

US$10,450.00

4.7· 32 Google reviewsLease from ~US$250/mo (60 mo), subject to credit approval · Get a lease quoteSection 179: placed in service by Dec 31, this purchase may be deductible for 2026 (ask your tax advisor) · How it works

Used ZEISS IOL Master 500 optical biometer with electric table — non-contact PCI biometry with telecentric keratometry and Haigis-L formula. 90-day warranty. Contact us.

Only 1 left in stock

Tested & inspectedEvery unit verified before it ships

Ships from FloridaUS & international

Secure checkoutCard or ACH (save 3.85%)

90-day warrantySe habla español
Top questions
Does it have a built-in printer?
No. The IOLMaster 500 prints to an external PostScript printer through its Ethernet port, with a network isolator. No printer is included.
What's included?
The IOLMaster 500, keyboard with touchpad, accessories case (forehead rest + calibration test target), user manual, power cable and electric table.
Does it measure dense cataracts?
Yes. It has more than 93% cataract penetration, with plausibility checks and a traffic-light indicator to reduce errors.
Which IOL formulas does it have?
SRK II, SRK/T, Holladay 1 & 2, Hoffer Q, Haigis and Haigis-L for post-LASIK, PRK and LASEK eyes.
📄 Get a formal quote (PDF)

For your purchasing department or accountant. Prices, shipping and payment options included.

SKU: US-IOL-ZEI-500-1

Description

What’s Included

  • ZEISS IOL Master 500 optical biometer (main unit)
  • Electric table
  • Test eye
  • Power cable
  • 90-day Digital Eye Center warranty

Condition & Warranty

Used. This unit has been tested and is in excellent working order, has been cleaned, and is ready to use once received; it shows some signs of normal clinical use, visible in the product photos. Covered by a 90-day warranty on parts and workmanship.

IOL Master 500 — Used Optical Biometer with Electric Table

ZEISS IOL Master 500 used optical biometer — front view with touchscreenThe ZEISS IOL Master 500 is a non-contact optical biometer built on partial coherence interferometry (PCI). In a single sitting the IOL Master 500 measures the four values that drive IOL power selection: axial length, corneal radii (keratometry), anterior chamber depth and white-to-white. Its distance-independent telecentric keratometry keeps K readings consistent even when the patient’s working distance varies slightly.

This used IOL Master 500 ships on its electric table, so it is ready for a dedicated biometry station in a cataract clinic or surgery center. Because measurements are optical and non-contact, there is no corneal anesthesia, no probe disinfection and no risk of corneal compression errors common with contact ultrasound biometry.

A study indexed by the National Library of Medicine compared the IOLMaster-500 with two other optical biometers and found comparable intraocular lens power prediction accuracy for cataract surgery planning.

Why Practices Choose the ZEISS IOL Master 500

ZEISS IOL Master 500 used — angled side view with joystick and chinrest

  • Optical PCI biometry — non-contact axial length measurement with no anesthesia and no probe contact
  • Telecentric keratometry — distance-independent corneal radii readings for dependable K values
  • Four parameters in one exam — axial length, keratometry, anterior chamber depth and white-to-white
  • Built-in IOL formulas — SRK II, SRK/T, Holladay 1 and 2, Hoffer Q, Haigis, plus Haigis-L for post-LASIK/PRK eyes
  • Chairside workflow — joystick alignment, integrated touchscreen display and electric table for comfortable patient positioning
  • Connectivity — data export to ZEISS FORUM and practice systems
  • Proven ZEISS platform — one of the most widely used optical biometers in cataract surgery

See the ZEISS IOL Master 500 in Action

This clip from ZEISS demonstrates distance-independent telecentric keratometry on the IOLMaster 500 optical biometer.

Clinical Applications

  • Pre-operative IOL power calculation for routine cataract surgery
  • IOL calculation after corneal refractive surgery using Haigis-L
  • Keratometry and anterior chamber depth data for toric and premium IOL planning
  • Axial length documentation and follow-up
  • White-to-white measurement for anterior segment planning

Who This Is For

  • Cataract and refractive surgery practices
  • Ambulatory surgery centers and hospital eye departments
  • Ophthalmology clinics replacing contact A-scan biometry
  • Practices that want a complete biometry station on its own table

Technical Specifications

Spec Detail
Model ZEISS IOLMaster 500
Type Non-contact optical biometer
Measurement technology Partial coherence interferometry (PCI)
Keratometry Distance-independent telecentric keratometry
Axial length range 14 – 38 mm (display 0.01 mm)
Corneal radii range 5 – 10 mm (display 0.01 mm)
Anterior chamber depth 1.5 – 6.5 mm (display 0.01 mm)
White-to-white 8 – 16 mm (display 0.1 mm)
IOL formulas SRK II, SRK/T, Holladay 1 & 2, Hoffer Q, Haigis, Haigis-L
Laser class Class 1
Table Electric table included
Condition Used
Warranty 90-day Digital Eye Center warranty

Compare ZEISS IOL Master Options

Feature IOL Master 500 w/ Table (this unit) IOL Master 500 (Used) IOLMaster 500 (Refurbished) IOL Master 5.5 w/ Table
Technology PCI optical biometry PCI optical biometry PCI optical biometry PCI optical biometry
Axial length range 14 – 38 mm 14 – 38 mm 14 – 38 mm 14 – 40 mm
Haigis-L formula Yes Yes Yes Yes
Electric table Included Not listed See listing Included
Condition Used Used Refurbished Used
Warranty 90-day 90-day 6-month 90-day
Price $10,450 $11,011 $12,825 $7,700

Also consider the refurbished ZEISS IOLMaster 500 for a longer warranty, or the IOL Master 5.5 with electric table for a lower-priced ZEISS biometry station.

Questions about the IOL Master 500? Contact us for availability and shipping details.

You may also like…