Description
What’s Included
- ZEISS CIRRUS CORNEA external lens
- ZEISS CIRRUS ANTERIOR CHAMBER external lens
- 6-month Digital Eye Center warranty
Condition & Warranty
Refurbished. Both lenses are inspected before shipping. Covered by a 6-month warranty on parts and workmanship. The anterior segment scans are a licensed software option on the CIRRUS itself — contact us if you need help confirming that the Anterior Segment Premier Module is active on your instrument.
Zeiss Cirrus Anterior Segment Lens Kit — Refurbished Ophthalmic Accessory
This refurbished Zeiss Cirrus anterior segment lens kit contains the two external lenses that CIRRUS HD-OCT uses for anterior imaging: the CORNEA lens and the ANTERIOR CHAMBER lens. On a CIRRUS 4000, 500, 5000 or 6000 with the Anterior Segment Premier Module, the CORNEA lens is used for HD Cornea and Pachymetry scans, and the ANTERIOR CHAMBER lens for Anterior Chamber and Wide Angle-to-Angle scans. The Zeiss Cirrus anterior segment workflow is similar to posterior scanning on the same instrument, so a practice that already owns a CIRRUS can add cornea, angle and anterior chamber imaging without a separate anterior segment OCT.
A review published through the National Library of Medicine describes how anterior segment OCT supports clinical care of the cornea, anterior chamber and iridocorneal angle, from corneal disease and refractive surgery to angle-closure glaucoma assessment.
Why Practices Choose the Zeiss Cirrus Anterior Segment Lens Kit

- Uses the CIRRUS you already own — the lenses attach to the instrument lens mount, so anterior segment imaging is added to an existing CIRRUS instead of buying a second OCT.
- Two lenses, four lens-based scans — CORNEA lens for HD Cornea and Pachymetry; ANTERIOR CHAMBER lens for Anterior Chamber and Wide Angle-to-Angle.
- Fits four CIRRUS generations — compatible with CIRRUS HD-OCT 4000, 500, 5000 and 6000.
- Scan list follows the lens — on CIRRUS 500/5000, lens-based anterior scans appear in the scan list once the lens is mounted; on the 4000 they are selected from the Lens menu.
- Quantitative angle metrics — Wide Angle-to-Angle analysis provides AOD 500/750, TISA 500/750 and scleral spur angle measurements.
- 9 mm pachymetry map — corneal thickness map with sector values and minimum thickness for refractive and keratoconus workups.
- Familiar CIRRUS workflow — acquisition uses the same Capture and Review steps operators already use for posterior scans.
Clinical Applications
- Refractive surgery screening and follow-up with pachymetry mapping and HD Cornea scans
- Keratoconus and corneal thinning assessment using corneal thickness maps
- Narrow-angle and angle-closure evaluation with Wide Angle-to-Angle measurements
- Anterior chamber depth and geometry documentation with ChamberView imaging
- Post-surgical corneal documentation, including residual stromal thickness measurement
Who This Is For
- Practices that own a CIRRUS 4000, 500, 5000 or 6000 and want anterior segment imaging on the same platform
- Cornea and refractive practices that need pachymetry and HD Cornea scans
- Glaucoma practices that want angle imaging alongside RNFL and optic nerve analysis
- Clinics replacing a lost or damaged CIRRUS anterior segment lens set
Technical Specifications
| Spec | Detail |
| Kit contents | CORNEA external lens and ANTERIOR CHAMBER external lens |
| Compatible instruments | ZEISS CIRRUS HD-OCT 4000, 500, 5000 and 6000 |
| CORNEA lens scans | HD Cornea (9 mm x 2 mm) and Pachymetry Map (9 mm diameter) |
| ANTERIOR CHAMBER lens scans | Anterior Chamber / ChamberView (15.5 mm x 5.8 mm max.) and Wide Angle-to-Angle (15.5 mm x 2.9 mm) |
| Angle analysis tools | AOD 500/750, TISA 500/750, scleral spur angle, angle and caliper tools |
| Cornea analysis | Residual stromal thickness, caliper tool; pachymetry sector values and minimum thickness |
| Mounting | Attaches to the CIRRUS instrument lens mount |
| Software requirement | Anterior Segment Premier Module license active on the host CIRRUS |
| Condition | Refurbished |
| Warranty | 6-month parts and workmanship |
Compare Zeiss Cirrus OCT Options
| Feature | Cirrus Anterior Segment Lens Kit (this) | Zeiss Cirrus 500 HD-OCT (Used) | Zeiss Cirrus 500 (Refurbished) | Zeiss Cirrus 5000 Rev 1 (Refurbished) |
| Type | External lens kit for CIRRUS | Complete SD-OCT system | Complete SD-OCT system | Complete SD-OCT system |
| Anterior segment external lenses | Included (Cornea + Anterior Chamber) | Add this kit | Add this kit | Add this kit |
| FastTrac retinal tracking | Not applicable | No | No | Yes |
| Condition | Refurbished | Used | Refurbished | Refurbished |
| Warranty | 6 months | 90 days | 6 months | 6 months |
| Price | $3,325 | $20,592 | $21,736 | $27,664 |
Need the complete system? The Zeiss Cirrus 500 (Refurbished) and the Zeiss Cirrus 500 HD-OCT (Used) accept this lens kit for anterior segment imaging.
Questions about the Zeiss Cirrus anterior segment lens kit? Contact us for availability and compatibility details.