Zeiss Cirrus 5000 OCT – Windows 10 – Used

US$27,500.00

4.7· 32 Google reviewsLease from ~US$659/mo (60 mo), subject to credit approval · Get a lease quoteSection 179: placed in service by Dec 31, this purchase may be deductible for 2026 (ask your tax advisor) · How it works

Used Zeiss Cirrus 5000 HD-OCT with FastTrac tracking and Windows 10, licensed for GPA, RNFL/ONH, macular and anterior chamber angle analyses; keyboard and power cable included. 90-day warranty. Contact us.

Only 1 left in stock

Tested & inspectedEvery unit verified before it ships

Ships from FloridaUS & international

Secure checkoutCard or ACH (save 3.85%)

90-day warrantySe habla español
Top questions
Does it have AngioPlex (OCT-A)?
No. This is a structural Cirrus 5000 without AngioPlex. For OCT-A, see the Cirrus 5000 with AngioPlex listings.
What's included?
The Cirrus 5000 HD-OCT with Windows 10, a keyboard and a power cable. No table is listed; the team can confirm.
Do you offer a Zeiss service contract?
No. We sell the equipment and are not a Zeiss-authorized service provider. This used unit has a 90-day Digital Eye Center warranty.
What scans does it do?
Licensed for ONH and RNFL Analysis, Guided Progression Analysis, macular reports and change analysis, and anterior chamber angle imaging, with FastTrac tracking and 5 µm axial resolution. No corneal pachymetry.
📄 Get a formal quote (PDF)

For your purchasing department or accountant. Prices, shipping and payment options included.

SKU: US-OCT-ZEI-CIR-5000-used

Description

What’s Included

  • Zeiss Cirrus 5000 HD-OCT with Windows 10
  • Keyboard
  • Power cable
  • 90-day Digital Eye Center warranty

Condition & Warranty

Used. Tested and in working order before listing, cleaned, with some cosmetic signs of use. Covered by a 90-day warranty on parts and workmanship.

Zeiss Cirrus 5000 HD-OCT — Used Spectral-Domain OCT

Zeiss Cirrus 5000 HD-OCT used — full view with keyboardThe Zeiss Cirrus 5000 is the Cirrus HD-OCT model with FastTrac retinal tracking: a spectral-domain OCT that scans at 27,000 A-scans per second with 5 µm axial resolution in tissue. This used zeiss cirrus 5000 runs Windows 10, and its licensed-features screen shows the core Cirrus glaucoma and retina analyses: ONH and RNFL Analysis, Guided Progression Analysis, Macular Change Analysis and Anterior Segment Imaging.

FastTrac uses a line-scanning ophthalmoscope to follow eye movement during acquisition, so repeat scans land in the same location visit after visit — the basis for reliable change and progression reports. The unit has no AngioPlex OCT angiography; if you need OCT-A, see the Cirrus 5000 AngioPlex options in the comparison below.

Anterior segment work on this unit is limited to the scans taken through the instrument’s internal lens, such as high-definition anterior chamber angle images. The external anterior segment lenses are not included, and corneal pachymetry maps require the Anterior Segment Premier option with the external cornea lens.

According to a National Library of Medicine-indexed study (BMC Ophthalmology, 2026), researchers used the Cirrus HD-OCT 5000 to establish normative peripapillary RNFL thickness values in healthy eyes — the same RNFL and optic nerve head analysis this unit is licensed to run.

Why Practices Choose the Zeiss Cirrus 5000

Zeiss Cirrus 5000 HD-OCT used — macular cube scan on display

  • FastTrac retinal tracking — LSO-based tracking reduces motion artifacts and re-scans the same location on follow-up visits.
  • Guided Progression Analysis — licensed on this unit for event- and trend-based glaucoma progression reports.
  • ONH and RNFL Analysis with normative data — optic nerve head and RNFL reports compared against the ONH normative database.
  • Macular reports and change analysis — macular thickness maps with normative data and visit-to-visit change.
  • Anterior Segment Imaging — licensed; anterior chamber angle scans through the internal lens.
  • 3D Volume Rendering and Segmentation Layer Editor — inspect cube scans in 3D and correct layer segmentation when needed.
  • Windows 10 — current operating system for the Cirrus software.

See the Zeiss Cirrus 5000 in Action

This demo from ZEISS walks through the CIRRUS HD-OCT platform and its scan workflow.

Clinical Applications

  • Glaucoma diagnosis and follow-up — RNFL thickness, optic nerve head parameters and Guided Progression Analysis.
  • Diabetic macular edema — macular thickness mapping and change over time.
  • Age-related macular degeneration — structural imaging of the retina and RPE for diagnosis and monitoring.
  • Retinal vein occlusion — tracking macular edema between treatments.
  • Anterior chamber angle assessment — angle imaging for narrow-angle evaluation.
  • Optic neuropathies — RNFL monitoring in neuro-ophthalmic disease.

Who This Is For

  • Optometry and ophthalmology practices adding a Zeiss Cirrus OCT with FastTrac.
  • Glaucoma-focused practices that rely on Guided Progression Analysis.
  • Groups already using Cirrus that want the same reports at another location.
  • Practices that need structural OCT and do not require OCT angiography or corneal pachymetry.

Technical Specifications

Specification Detail
Manufacturer Carl Zeiss Meditec
Model Cirrus HD-OCT 5000
Technology Spectral-domain OCT
Light source Superluminescent diode, 840 nm
Scan speed 27,000 A-scans per second
Axial resolution 5 µm (in tissue)
Transverse resolution 15 µm (in tissue)
Scan depth 2.0 mm (in tissue)
Retinal tracking FastTrac with line-scanning ophthalmoscope
Licensed analyses on this unit ONH and RNFL Analysis, ONH Normative Data, Guided Progression Analysis, Macular Reports, Macular Normative Data, Macular Change Analysis, Single Eye Summary Analysis, Anterior Segment Imaging, 3D Volume Rendering, Segmentation Layer Editor
Anterior segment Internal-lens scans (anterior chamber angle); external lens kit not included; no corneal pachymetry
OCT angiography Not included
Operating system Windows 10
Included accessories Keyboard, power cable
Condition Used — tested before listing
Warranty 90-day warranty on parts and workmanship

Compare Zeiss Cirrus OCT Options

Feature Cirrus 5000 (this unit) Cirrus 500 Used Cirrus 5000A AngioPlex Refurbished Cirrus 5000 AngioPlex Used
Condition Used Used Refurbished Used
Scan speed 27,000 A-scans/sec 27,000 A-scans/sec 27,000–68,000 A-scans/sec 27,000–68,000 A-scans/sec
Fundus view Line-scanning ophthalmoscope Live OCT fundus image Line-scanning ophthalmoscope Line-scanning ophthalmoscope
FastTrac tracking Yes No Yes Yes
OCT angiography No No AngioPlex AngioPlex
Operating system Windows 10 Windows 10 Windows 10 Windows 10
Electric table — Included Included —
Warranty 90 days 90 days 6 months 90 days
Price $27,500 $19,800 $35,200 $40,700

The same model is also available as a refurbished Zeiss Cirrus 5000 with electric table. For expanded anterior segment scans on a Cirrus with the Anterior Segment Premier license, see the Zeiss Anterior Segment Lens Kit for Cirrus OCT, which adds the external cornea and anterior chamber lenses.

Questions about the Zeiss Cirrus 5000 HD-OCT? Contact us for availability and shipping details.

Additional information

Brand

You may also like…