Zeiss Visulas LSL 532s Green Laser Photocoagulator – Used

SKU: US-LAS-ZEI-VIS-LSL-532S

US$14,300.00

Used ZEISS Visulas 532s laser — 532 nm retinal photocoagulator with 50–1,000 µm spot sizing, five-step magnification and an integrated laser slit lamp. 90-day warranty. Contact us.

Out of stock

Description

CURRENTLY SOLD OUTWe Can Source This For You

This exact unit sold recently — but we specialize in sourcing refurbished ophthalmic equipment. Typical turnaround is 2–4 weeks once we confirm availability with our partners. Request a free quote with no deposit required.

Request Availability → Free quote · No obligation · 90-day warranty when shipped

What’s Included

  • ZEISS Visulas 532s laser slit lamp with flexible fixation light
  • Visulas 532s laser unit (mounted under the table)
  • Touchscreen control panel
  • ZEISS instrument table with base
  • Foot switch
  • 90-day Digital Eye Center warranty

Condition & Warranty

Used. The unit is in working condition with no errors found. It has been cleaned and shows some signs of prior clinical use. We recommend a technician inspection before first clinical use. Covered by a 90-day Digital Eye Center warranty on parts and workmanship.

Zeiss Visulas 532s Laser — Used Retinal Photocoagulator

Zeiss Visulas LSL 532s used - front view green laser photocoagulator The ZEISS Visulas 532s laser is a 532 nm ophthalmic photocoagulation system built for retinal laser therapy. It uses a frequency-doubled, diode-pumped solid-state source and delivers the treatment beam through an integrated laser slit lamp, so the physician can visualize and precisely target the treatment area under direct view.

This Zeiss Visulas 532s laser provides an adjustable treatment spot from 50 to 1,000 µm without a contact lens, with larger spots available depending on the contact lens used. The integrated slit lamp offers five magnification steps from 5× to 32×, while the servo-electric micromanipulator supports precise, synchronous positioning of the laser beam and slit illumination. Pulse durations are adjustable from 10 to 2,500 ms in continuous-wave mode, with a maximum power of 1.5 W at the cornea.

The 532 nm green wavelength is well absorbed by hemoglobin and the retinal pigment epithelium, which is why it is a long-standing workhorse for retinal photocoagulation. The National Library of Medicine documents panretinal photocoagulation as an established treatment for proliferative diabetic retinopathy.

Why Practices Choose the Zeiss Visulas LSL 532s

Zeiss Visulas LSL 532s used - side view integrated laser slit lamp

  • 532 nm green wavelength — strongly absorbed by hemoglobin and the RPE for effective, targeted retinal photocoagulation.
  • Wide spot range — 50 to 1,000 µm without a contact lens lets the physician match spot size to the clinical task.
  • Integrated laser slit lamp — treatment beam and illumination share the same optics, so aiming and delivery stay coaxial and under direct view.
  • Servo-electric micromanipulator — sensitive, synchronous positioning of the laser beam and slit illumination.
  • Adjustable pulse duration — 10 to 2,500 ms continuous-wave control for fine dosing across indications.
  • True-to-color safety filter — the physician protection filter preserves a natural-color view of the fundus during treatment.
  • Diode-pumped solid-state source — thermoelectric cooling supports stable, reproducible laser output.

Clinical Applications

  • Panretinal photocoagulation for proliferative diabetic retinopathy
  • Focal and grid laser for diabetic macular edema
  • Treatment of retinal tears and peripheral retinal degenerations
  • Laser therapy for retinal vascular disease, including vein occlusions
  • Selected glaucoma applications such as laser trabeculoplasty

Who This Is For

  • Retina specialists building or expanding an in-office laser suite
  • Ophthalmology practices adding photocoagulation capability without a new-equipment budget
  • Clinics and ASCs that want a proven ZEISS laser platform with slit-lamp delivery
  • Group practices standardizing on green-wavelength retinal laser therapy

Technical Specifications

Specification Detail
Instrument type Ophthalmic retinal photocoagulation laser
Manufacturer ZEISS
Model Visulas 532s / LSL 532s
Laser type Frequency-doubled, diode-pumped solid-state laser
Laser wavelength 532 nm (green)
Maximum power at cornea 1.5 W
Aiming beam Diode, 620–650 nm, adjustable brightness (max 1 mW)
Pulse duration 10–2,500 ms, continuous wave
Treatment spot size 50–1,000 µm without contact lens
Slit width 0–14 mm continuously adjustable
Slit length 1 / 3 / 5 / 9 / 14 mm
Magnification 5×, 8×, 12×, 20×, 32×
Physician safety filter True-to-color
Micromanipulator Servo-electric
Electrical connection 100–240 V, 50/60 Hz
Condition Used
Warranty 90-day Digital Eye Center warranty

Compare Ophthalmic Laser Options

Feature Zeiss Visulas 532s Coherent Aura
Laser type 532 nm green photocoagulator Nd:YAG
Primary use Retinal photocoagulation Posterior capsulotomy / iridotomy
Delivery Integrated laser slit lamp Slit-lamp delivery
Condition Used Used
Price $14,300 $8,250

Also consider the Coherent Aura YAG laser if your practice needs an Nd:YAG system for capsulotomy and iridotomy rather than retinal photocoagulation.

Questions about the Zeiss Visulas 532s laser? Contact us for availability and shipping details.