Description
What’s Included
- Optovue iVue Spectral-Domain OCT Engine (26,000 A-scans/second, 5 µm axial resolution)
- iCam Non-Mydriatic Fundus Camera Module (5.2 MP, 45° field of view)
- Medical-Grade Electric Elevation Table (motorized vertical positioning)
- Integrated Optovue Software Suite (retinal, optic nerve, glaucoma, anterior segment protocols)
- Complete cables, accessories, and operator documentation
- 90-day warranty on parts and workmanship
Condition & Warranty
Used. Fully tested and confirmed in excellent working condition. The SD-OCT engine delivers sharp, high-resolution cross-sectional scans with consistent 5 µm axial precision. The iCam module produces crisp, high-resolution color fundus images. The electric table operates smoothly across its full vertical range. Minor cosmetic wear. Covered by a 90-day warranty on parts and workmanship.
Optovue iFusion iCam — Used Combined OCT & Fundus Camera

Research published in the National Library of Medicine confirms that combining structural OCT imaging with synchronized color fundus photography significantly enhances diagnostic accuracy for age-related macular degeneration, diabetic macular edema, glaucoma, and anterior segment pathology.
Why Practices Choose the Optovue iFusion iCam
- True Dual-Modality Integration — SD-OCT and fundus photography in a single unit without patient repositioning
- Ultra-Fast OCT Scanning — 26,000 A-scans per second with high-density retinal imaging protocols
- Exceptional Depth Resolution — 5 µm axial resolution enables precise early disease detection and layer segmentation
- Non-Mydriatic Fundus Imaging — 5.2 MP, 45° field-of-view color imaging through small pupils without dilation
- Comprehensive Analysis Protocols — Retinal thickness, RNFL, optic nerve head, GCC segmentation, anterior segment
- Integrated Electric Table — Motorized vertical positioning for all patient demographics, included with the system
- Normative Comparison Databases — Built-in glaucoma risk stratification and longitudinal trend tracking
Clinical Applications
- Glaucoma Screening & Management — RNFL thickness mapping with simultaneous optic nerve fundus documentation
- Age-Related Macular Degeneration — High-resolution retinal layer assessment for early detection and progression monitoring
- Diabetic Macular Edema — Precise retinal thickness quantification co-registered with color fundus documentation
- Diabetic Retinopathy — Automated layer segmentation, thickness trending, and photo documentation in one visit
- Anterior Segment Evaluation — Corneal pachymetry, anterior chamber depth measurement, lens opacity assessment
- Optic Nerve Disorders — GCC segmentation to differentiate glaucomatous from non-glaucomatous neuropathy
Who This Is For
- Comprehensive Ophthalmology & Optometry Practices — Advanced dual-modality imaging without expanding clinic footprint
- High-Volume Screening Suites — Rapid unified documentation for diabetic retinopathy and glaucoma programs
- Specialty Retinal & Glaucoma Clinics — Objective structural imaging with co-registered fundus photos for diagnosis and follow-up
- Research & Academic Institutions — Multi-protocol retinal disease studies requiring both structural and photographic data
Technical Specifications
| Specification | Detail |
| System Name | Optovue iFusion (iVue SD-OCT + iCam Fundus Camera) |
| OCT Technology | Spectral-Domain (SD-OCT) |
| Scan Speed | 26,000 A-scans per second |
| Axial Resolution | 5 µm (in tissue) |
| Transverse Resolution | 15 µm at retina |
| Scan Beam Wavelength | 840 nm ± 10 nm |
| Fundus Camera | iCam — 5.2 MP, 45° field of view, non-mydriatic |
| Minimum Pupil Size | 4.0 mm (non-mydriatic operation) |
| Working Distance (Retina) | 21.2 mm |
| Working Distance (Cornea) | 16.6 mm |
| Motorized Focus Range | -15D to +10D |
| Scan Protocols | Retinal, Glaucoma (RNFL/GCC), Anterior Segment, Macula |
| Electric Table | Integrated, motorized vertical positioning |
| Condition | Used (fully tested, excellent working condition) |
| Warranty | 90-day parts and workmanship |
Compare Diagnostic Imaging Options
| Feature | Optovue iFusion iCam | Zeiss Cirrus 500 | Zeiss Clarus 500 |
| Type | SD-OCT + Fundus Camera (combined) | SD-OCT only | Ultra-widefield camera only |
| OCT Technology | SD-OCT, 26,000 A-scans/sec, 5 µm | SD-OCT, 27,000 A-scans/sec, 5 µm | None |
| Fundus Imaging | 5.2 MP, 45° non-mydriatic | None | 133°–200° multi-modal (True Color, FAF, IR) |
| Electric Table | Included | Not included | Not included |
| Condition | Used | Refurbished | Used |
| Warranty | 90 days | 6 months | 90 days |
| Price | $18,700 | $20,900 | $27,500 |
Also consider: Zeiss Cirrus 500 OCT for standalone SD-OCT, or the Zeiss Clarus 500 for ultra-widefield retinal imaging.
Support & Resources
Every Optovue iFusion iCam system includes complete documentation and technical support. We provide post-sale guidance on setup, operation, and optimization. For advanced training, we can connect you with Optovue’s authorized service network. Contact us with any questions.