Optovue iFusion + iCam Combined OCT & Camera w/ Electric Table – Used

SKU: US-RC-OPT-IFUSION

US$18,700.00

Used Optovue iFusion iCam — Combined SD-OCT & non-mydriatic fundus camera. 26,000 A-scans/second, 5 µm axial resolution, 5.2 MP / 45° iCam, integrated electric table. 90-day warranty. Contact us.

Description

What’s Included

  • Optovue iVue Spectral-Domain OCT Engine (26,000 A-scans/second, 5 µm axial resolution)
  • iCam Non-Mydriatic Fundus Camera Module (5.2 MP, 45° field of view)
  • Medical-Grade Electric Elevation Table (motorized vertical positioning)
  • Integrated Optovue Software Suite (retinal, optic nerve, glaucoma, anterior segment protocols)
  • Complete cables, accessories, and operator documentation
  • 90-day warranty on parts and workmanship

Condition & Warranty

Used. Fully tested and confirmed in excellent working condition. The SD-OCT engine delivers sharp, high-resolution cross-sectional scans with consistent 5 µm axial precision. The iCam module produces crisp, high-resolution color fundus images. The electric table operates smoothly across its full vertical range. Minor cosmetic wear. Covered by a 90-day warranty on parts and workmanship.

Optovue iFusion iCam — Used Combined OCT & Fundus Camera

Optovue iFusion iCam OCT and fundus camera system with electric tableThe Optovue iFusion iCam combines the iVue spectral-domain OCT with the iCam high-resolution fundus camera in a single diagnostic platform. This Optovue iFusion iCam system integrates both imaging modalities, eliminating the need to reposition patients between devices and dramatically improving workflow efficiency in high-volume screening environments.

Research published in the National Library of Medicine confirms that combining structural OCT imaging with synchronized color fundus photography significantly enhances diagnostic accuracy for age-related macular degeneration, diabetic macular edema, glaucoma, and anterior segment pathology.

Why Practices Choose the Optovue iFusion iCam

  • True Dual-Modality Integration — SD-OCT and fundus photography in a single unit without patient repositioning
  • Ultra-Fast OCT Scanning — 26,000 A-scans per second with high-density retinal imaging protocols
  • Exceptional Depth Resolution — 5 µm axial resolution enables precise early disease detection and layer segmentation
  • Non-Mydriatic Fundus Imaging — 5.2 MP, 45° field-of-view color imaging through small pupils without dilation
  • Comprehensive Analysis Protocols — Retinal thickness, RNFL, optic nerve head, GCC segmentation, anterior segment
  • Integrated Electric Table — Motorized vertical positioning for all patient demographics, included with the system
  • Normative Comparison Databases — Built-in glaucoma risk stratification and longitudinal trend tracking

Clinical Applications

  • Glaucoma Screening & Management — RNFL thickness mapping with simultaneous optic nerve fundus documentation
  • Age-Related Macular Degeneration — High-resolution retinal layer assessment for early detection and progression monitoring
  • Diabetic Macular Edema — Precise retinal thickness quantification co-registered with color fundus documentation
  • Diabetic Retinopathy — Automated layer segmentation, thickness trending, and photo documentation in one visit
  • Anterior Segment Evaluation — Corneal pachymetry, anterior chamber depth measurement, lens opacity assessment
  • Optic Nerve Disorders — GCC segmentation to differentiate glaucomatous from non-glaucomatous neuropathy

Who This Is For

  • Comprehensive Ophthalmology & Optometry Practices — Advanced dual-modality imaging without expanding clinic footprint
  • High-Volume Screening Suites — Rapid unified documentation for diabetic retinopathy and glaucoma programs
  • Specialty Retinal & Glaucoma Clinics — Objective structural imaging with co-registered fundus photos for diagnosis and follow-up
  • Research & Academic Institutions — Multi-protocol retinal disease studies requiring both structural and photographic data

Technical Specifications

Specification Detail
System Name Optovue iFusion (iVue SD-OCT + iCam Fundus Camera)
OCT Technology Spectral-Domain (SD-OCT)
Scan Speed 26,000 A-scans per second
Axial Resolution 5 µm (in tissue)
Transverse Resolution 15 µm at retina
Scan Beam Wavelength 840 nm ± 10 nm
Fundus Camera iCam — 5.2 MP, 45° field of view, non-mydriatic
Minimum Pupil Size 4.0 mm (non-mydriatic operation)
Working Distance (Retina) 21.2 mm
Working Distance (Cornea) 16.6 mm
Motorized Focus Range -15D to +10D
Scan Protocols Retinal, Glaucoma (RNFL/GCC), Anterior Segment, Macula
Electric Table Integrated, motorized vertical positioning
Condition Used (fully tested, excellent working condition)
Warranty 90-day parts and workmanship

Compare Diagnostic Imaging Options

Feature Optovue iFusion iCam Zeiss Cirrus 500 Zeiss Clarus 500
Type SD-OCT + Fundus Camera (combined) SD-OCT only Ultra-widefield camera only
OCT Technology SD-OCT, 26,000 A-scans/sec, 5 µm SD-OCT, 27,000 A-scans/sec, 5 µm None
Fundus Imaging 5.2 MP, 45° non-mydriatic None 133°–200° multi-modal (True Color, FAF, IR)
Electric Table Included Not included Not included
Condition Used Refurbished Used
Warranty 90 days 6 months 90 days
Price $18,700 $20,900 $27,500

Also consider: Zeiss Cirrus 500 OCT for standalone SD-OCT, or the Zeiss Clarus 500 for ultra-widefield retinal imaging.