Centervue DRS Fundus Camera – Used

US$5,423.00

4.7· 30 Google reviews

Used CenterVue DRS fundus camera — automated non-mydriatic retinal imaging with auto-alignment, autofocus and a 45° × 40° field; includes power cable and dust cover. 90-day Digital Eye Center warranty. Contact us.

Only 1 left in stock

Tested & inspectedEvery unit verified before it ships

Ships from FloridaUS & international

Secure checkoutCard or ACH (save 3.85%)

90-day warrantySe habla español
Top questions
Do patients need to be dilated?
No. The DRS is non-mydriatic and works through pupils as small as 4.0 mm.
What's included?
The DRS camera, power cable and dust cover. Nothing else is listed for this unit.
Can it send images to my EMR or network?
The model exports JPEG, DICOM or PDF to a network folder and JPG to USB; EMR integration needs a license. A team member can confirm this unit's setup.
Do I need a separate computer?
No. It has an integrated computer and touchscreen, so you can capture and review images on the unit.
📄 Get a formal quote (PDF)

For your purchasing department or accountant. Prices, shipping and payment options included.

SKU: US-RC-CEN-DRS

Description

What’s Included

  • CenterVue DRS fundus camera
  • Power cable
  • Dust cover
  • 90-day Digital Eye Center warranty

Condition & Warranty

Used. This unit has been tested, cleaned and is in excellent working order; it shows some signs of previous use, visible in the product photos. Covered by a 90-day warranty on parts and workmanship.

CenterVue DRS Fundus Camera — Used Automated Retinal Camera

CenterVue DRS fundus camera used — three-quarter view with touchscreenThe CenterVue DRS fundus camera is a fully automated, non-mydriatic retinal camera that captures 45° × 40° color images of the fundus without pharmacological dilation. Once the patient is seated at the chin rest, the CenterVue DRS fundus camera aligns itself to the center of the pupil, focuses and captures the image, so technicians can obtain consistent retinal photographs with minimal training.

A 5-megapixel sensor resolves 48 pixels per degree across the field, and a focus range of −15 D to +15 D covers most refractive errors. The integrated computer and touchscreen let the operator acquire, review and manage images directly on this used CenterVue DRS fundus camera — no separate workstation is required to start imaging.

Non-mydriatic fundus photography is widely used for diabetic retinopathy detection; a systematic review indexed by the National Library of Medicine compares the diagnostic accuracy of photographic methods for detecting diabetic retinopathy.

Why Practices Choose the CenterVue DRS

CenterVue DRS fundus camera used — multi-field fixation settings screen

  • Non-mydriatic imaging — captures color retinal images through a pupil as small as 4.0 mm, keeping screening visits short.
  • Automatic alignment, focus and capture — the camera centers on the pupil, focuses and fires on its own, reducing operator-to-operator variability.
  • 45° × 40° field — a wide single-field view of the posterior pole, optic disc and macula.
  • Seven internal fixation targets — central and peripheral fields can be acquired for broader retinal coverage.
  • OD/OS selection — the operator captures the right eye, left eye or both in one session.
  • All-in-one design — integrated computer and touchscreen in a compact standalone unit.

See the CenterVue DRS in Action

This short clip shows the CenterVue DRS being used to capture retinal images in a clinical setting.

Clinical Applications

  • Diabetic retinopathy screening and follow-up.
  • Documentation of the optic disc for glaucoma evaluation.
  • Monitoring of age-related macular degeneration.
  • Baseline retinal photography in routine comprehensive exams.
  • Documentation of retinal vascular changes.

Who This Is For

  • Optometry and ophthalmology practices adding retinal photography.
  • Primary care and endocrinology clinics running diabetic eye screening.
  • Screening programs that rely on technicians rather than photographers.
  • Practices looking for an automated camera at a used-equipment price point.

Technical Specifications

Spec Detail
Manufacturer CenterVue
Model DRS (Digital Retinography System)
Equipment type Automated non-mydriatic color fundus camera
Field of view 45° horizontal × 40° vertical
Image sensor 5 megapixels (2592 × 1944)
Sensor resolution 48 pixels/degree
Minimum pupil diameter 4.0 mm
Focus range −15 D to +15 D
Automation Auto-alignment to pupil center, autofocus and automatic capture
Fixation targets 7 internal targets (central, nasal, temporal, superior, inferior, supero-temporal, peri-central fields)
Eye selection OD, OS or both, selected by the operator
Operation Standalone unit with integrated computer and touchscreen display
Included accessories Power cable and dust cover
Condition Used
Warranty 90-day Digital Eye Center warranty on parts and workmanship

Compare Non-Mydriatic Fundus Camera Options

Feature CenterVue DRS (this unit) Topcon TRC-NW400 Zeiss Visucam Pro NM
Field of view 45° × 40° 45° / 30° 45° / 30°
Minimum pupil 4.0 mm 3.3 mm (small-pupil mode) 4.0 mm at 45°; 3.3 mm at 30°
Automation Auto-alignment, autofocus, auto-capture Auto-alignment, autofocus, auto-capture —
Included extras Power cable, dust cover Power cable, dust cover Electric table
Condition / warranty Used / 90-day Used / 90-day Used / 90-day
Price $5,148 $7,601 $5,720

Need a portable option for outreach screening? See the Welch Allyn RetinaVue 700 handheld retinal camera.

Questions about the CenterVue DRS? Contact us for availability and shipping details.

You may also like…