Reichert 7cr Auto Tonometer – Used

SKU: US-TON-REI-7cr

US$3,850.00

Used Reichert 7 auto tonometer (7cr) — non-contact IOP with Corneal Hysteresis (CH) and IOPcc, one-touch auto-alignment, 3-reading average, built-in printer. 90-day warranty. Contact us.

Out of stock

Description

CURRENTLY SOLD OUTWe Can Source This For You

This exact unit sold recently — but we specialize in sourcing refurbished ophthalmic equipment. Typical turnaround is 2–4 weeks once we confirm availability with our partners. Request a free quote with no deposit required.

Request Availability → Free quote · No obligation · 90-day warranty when shipped

What's Included

  • Reichert 7cr Auto Tonometer main unit
  • Power cable
  • Instruction manual
  • 90-day Digital Eye Center warranty

Condition & Warranty

Used. Inspected and tested for accurate IOP, CH, and IOPcc measurement prior to shipping. May show cosmetic wear consistent with prior clinical use; fully operational. Covered by a 90-day warranty on parts and workmanship.

Reichert 7 Auto Tonometer Used — Corneal Hysteresis NCT

Reichert 7cr auto tonometer used — front view non-contact IOP station The Reichert 7 auto tonometer is the most clinically advanced non-contact tonometer in the Reichert lineup — the 7cr variant adds Corneal Hysteresis (CH) and corneal-compensated IOP (IOPcc) to the standard air-puff workflow, delivering a biomechanically adjusted picture of true IOP that standard NCTs simply cannot provide. This used reichert 7 auto tonometer pairs one-touch auto-alignment and a 3-reading average with a built-in thermal printer, making it a complete, technician-friendly IOP station that requires no special training to operate. For practices seeing glaucoma suspects, post-refractive surgery patients, or any population where corneal properties affect pressure readings, the Reichert 7 auto tonometer provides the clinical depth to flag risk at the pre-test lane before the physician exam begins.

The National Library of Medicine confirms that intraocular pressure directly correlates with progressive retinal nerve fiber layer loss in glaucoma patients, underscoring the clinical importance of accurate, biomechanically adjusted IOP measurements — precisely what Corneal Hysteresis and IOPcc are designed to provide.

Why Practices Choose the Reichert 7 Auto Tonometer

  • Reichert 7cr auto tonometer used — color LCD display with live waveformCorneal Hysteresis (CH) measurement — the 7cr reports CH alongside IOP on every measurement; CH is a biomechanical indicator of corneal rigidity that correlates independently with glaucoma progression risk and cannot be obtained from any standard air-puff NCT.
  • IOPcc — corneal-compensated IOP — adjusts for individual corneal biomechanical properties rather than applying a universal central corneal thickness correction, providing a more accurate true IOP estimate across the full patient population.
  • IOPg — Goldmann-correlated IOP — also reported on every measurement slip, allowing direct comparison with historical Goldmann applanation data without disrupting continuity of care for existing patients.
  • One-touch auto-alignment — automatic positioning eliminates manual joystick fine-alignment, ensuring reproducible results across operators and reducing measurement variability in busy pre-testing lanes.
  • 3-reading automatic average per eye — captures and averages three measurements per session; outlier readings are flagged, and the mean is presented cleanly for the physician without extra technician steps.
  • Real-time waveform display — live applanation signal shown on the color LCD during measurement, allowing the technician to confirm signal quality before committing to the result.
  • Built-in thermal printer — produces a result slip with IOPcc, IOPg, and CH values side by side, ready for the patient chart before the physician exam begins.
  • No-touch patient experience — non-contact measurement eliminates topical anesthetic, reduces patient hesitation, and removes cross-contamination risk compared to contact tonometry methods.

Clinical Applications

  • Glaucoma screening and monitoring — CH and IOPcc values build a richer glaucoma risk profile than IOP alone, supporting earlier intervention decisions and more confident long-term monitoring.
  • Glaucoma suspect triage — borderline IOP patients with low CH can be identified pre-exam, allowing the physician to allocate more workup time where risk is highest before entering the exam room.
  • Post-refractive surgery IOP measurement — IOPcc corrects for the corneal thinning from LASIK and PRK that causes standard tonometers to systematically underestimate IOP in post-surgical eyes.
  • Pre-operative refractive surgery screening — CH provides a complementary biomechanical assessment of corneal integrity for patients being evaluated for LASIK or PRK candidacy.
  • Routine pre-testing IOP — for practices replacing a basic air-puff NCT, the 7cr provides a comprehensive IOP dataset at every pre-testing visit without adding chair time or workflow steps.

Who This Is For

  • Glaucoma-focused practices that want CH and IOPcc data in the pre-testing lane without purchasing a new Ocular Response Analyzer or equivalent biomechanics device.
  • General ophthalmology offices upgrading from a basic NCT to a tonometer that provides clinically richer IOP data at every visit.
  • Refractive surgery programs managing post-LASIK/PRK patients where standard air-puff measurements systematically underestimate true intraocular pressure.
  • Multi-physician practices equipping additional pre-testing lanes with a proven, technician-friendly NCT that requires no special training to operate reliably.

Technical Specifications

Specification Detail
Manufacturer Reichert Technologies
Model 7cr Auto Tonometer
Measurement Type Non-contact (air puff)
IOP Range 5–60 mmHg
Corneal Hysteresis (CH) Yes
IOPcc (corneal-compensated) Yes
IOPg (Goldmann-correlated) Yes
Readings per Measurement 3 automatic, averaged
Alignment Automatic one-touch
Display Color LCD with live waveform
Output Built-in thermal printer
Mounting Standard table arm
Power 110–240 V AC, 50/60 Hz
Condition Used
Warranty 90 days

Compare Reichert Tonometer Options

Feature Reichert 7cr NCT TonoPen XL Diaton Tonometer
Measurement Type Non-contact (air puff) Contact (handheld) Transpalpebral (non-corneal)
Corneal Hysteresis Yes (CH + IOPcc) No No
Auto-alignment Yes (one-touch) Manual Manual
Condition Used Refurbished New
Warranty 90 days 6 months 1 year

Also available: Reichert Package (RK-700 + LensChek Pro + 7cr) — bundles this tonometer with an autorefractor and lensmeter at a significant combined savings for practices equipping a full pre-test lane.

Similar Tonometers In Stock Now

Need a comparable tonometer available today? These units are in stock and ready to ship with a 90-day Digital Eye Center warranty.

Prefer to wait for the Reichert 7cr Auto Tonometer – Used? Request availability and we’ll source one for you.

Questions about the Reichert 7 auto tonometer? Contact us for availability and shipping details.

Additional information

Weight 65 lbs
Dimensions 24 × 24 × 24 in