Zeiss Cirrus 5000 OCT – Windows 10 – Used

SKU: US-OCT-ZEI-CIR-5000-used

US$28,600.00

Lease from ~US$698/mo · 48 mo, OAC · Get a lease quote

Used Zeiss Cirrus 5000 HD-OCT with FastTrac retinal tracking, Guided Progression Analysis, ONH/RNFL and macular analyses, Anterior Segment Imaging and Windows 10. Includes keyboard and power cable. 90-day warranty. Contact us.

Only 1 left in stock

Tested & inspectedEvery unit verified before it ships

Ships from FloridaUS & international

Secure checkoutCard or ACH (save 3.85%)

90-day warrantySe habla español
Top questions
Does it have AngioPlex (OCT-A)?
No. This is a structural Cirrus 5000 without AngioPlex. For OCT-A, see the Cirrus 5000 with AngioPlex listings.
What's included?
The Cirrus 5000 OCT, the Windows 10 workstation with Cirrus software and power cabling. No table is listed; the team can confirm.
Do you offer a Zeiss service contract?
No. We sell the equipment and are not a Zeiss-authorized service provider. This used unit has a 90-day Digital Eye Center warranty.
What scans does it do?
Macular Cube, Optic Disc Cube, PanoMap and Ganglion Cell Analysis, with FastTrac retinal tracking and 5 µm axial resolution.
📄 Get a formal quote (PDF)

For your purchasing department or accountant. Prices, shipping and payment options included.

Description

What’s Included

  • Zeiss Cirrus 5000 HD-OCT with Windows 10
  • Keyboard
  • Power cable
  • 90-day Digital Eye Center warranty

Condition & Warranty

Used. Tested and in working order before listing, cleaned, with some cosmetic signs of use. Covered by a 90-day warranty on parts and workmanship.

Zeiss Cirrus 5000 HD-OCT — Used Spectral-Domain OCT

Zeiss Cirrus 5000 HD-OCT used — full view with keyboardThe Zeiss Cirrus 5000 is the Cirrus HD-OCT model with FastTrac retinal tracking: a spectral-domain OCT that scans at 27,000 A-scans per second with 5 µm axial resolution in tissue. This used zeiss cirrus 5000 runs Windows 10 and has the core Cirrus glaucoma and retina analyses licensed — ONH and RNFL Analysis, Guided Progression Analysis, Macular Change Analysis and Anterior Segment Imaging.

FastTrac uses a 20 Hz line-scanning ophthalmoscope to follow eye movement during acquisition, so repeat scans land in the same location visit after visit — the basis for reliable change and progression reports. The unit has no AngioPlex OCT angiography; if you need OCT-A, see the Cirrus 5000 AngioPlex options in the comparison below.

According to a National Library of Medicine-indexed study (BMC Ophthalmology, 2026), researchers used the Cirrus HD-OCT 5000 to establish normative peripapillary RNFL thickness values in 756 healthy eyes — the same RNFL and optic nerve head analysis this unit is licensed to run.

Why Practices Choose the Zeiss Cirrus 5000

Zeiss Cirrus 5000 HD-OCT used — macular cube scan on display

  • FastTrac retinal tracking — 20 Hz LSO tracking reduces motion artifacts and re-scans the same location on follow-up visits.
  • Guided Progression Analysis — licensed on this unit for event- and trend-based glaucoma progression reports.
  • ONH and RNFL Analysis with normative data — optic nerve head and RNFL reports compared against the ONH normative database.
  • Macular reports and change analysis — macular thickness maps with normative data and visit-to-visit change.
  • Anterior Segment Imaging — licensed; HD Angle scans of the anterior chamber angle without an external lens.
  • 3D Volume Rendering and Segmentation Layer Editor — inspect cube scans in 3D and correct layer segmentation when needed.
  • Windows 10 — current operating system for the Cirrus software.

See the Zeiss Cirrus 5000 in Action

This demo from ZEISS walks through the CIRRUS HD-OCT platform and its scan workflow.

Clinical Applications

  • Glaucoma diagnosis and follow-up — RNFL thickness, optic nerve head parameters and Guided Progression Analysis.
  • Diabetic macular edema — macular thickness mapping and change over time.
  • Age-related macular degeneration — structural imaging of the retina and RPE for diagnosis and monitoring.
  • Retinal vein occlusion — tracking macular edema between treatments.
  • Anterior chamber angle assessment — HD Angle imaging for narrow-angle evaluation.
  • Optic neuropathies — RNFL monitoring in neuro-ophthalmic disease.

Who This Is For

  • Optometry and ophthalmology practices adding a Zeiss Cirrus OCT with FastTrac.
  • Glaucoma-focused practices that rely on Guided Progression Analysis.
  • Groups already using Cirrus that want the same reports at another location.
  • Practices that need structural OCT and do not require OCT angiography.

Technical Specifications

Specification Detail
Manufacturer Carl Zeiss Meditec
Model Cirrus HD-OCT 5000
Technology Spectral-domain OCT
Light source Superluminescent diode, 840 nm
Scan speed 27,000 A-scans per second
Axial resolution 5 µm (in tissue)
Transverse resolution 15 µm (in tissue)
Scan depth 2.0 mm (in tissue)
Retinal tracking FastTrac with 20 Hz line-scanning ophthalmoscope
Licensed analyses on this unit ONH and RNFL Analysis, ONH Normative Data, Guided Progression Analysis, Macular Reports, Macular Normative Data, Macular Change Analysis, Single Eye Summary Analysis, Anterior Segment Imaging, 3D Volume Rendering, Segmentation Layer Editor
OCT angiography Not included
Operating system Windows 10
Included accessories Keyboard, power cable
Condition Used — tested before listing
Warranty 90-day warranty on parts and workmanship

Compare Zeiss Cirrus OCT Options

Feature Cirrus 5000 (this unit) Cirrus 500 HD-OCT Cirrus 5000 Rev 1 Cirrus 5000A AngioPlex Cirrus 5000 AngioPlex
Condition Used Used Refurbished Refurbished Used
Scan speed 27,000 A-scans/sec 27,000 A-scans/sec 27,000 A-scans/sec 68,000 A-scans/sec 27,000–68,000 A-scans/sec
FastTrac tracking Yes No Yes Yes Yes
OCT angiography No No No AngioPlex AngioPlex
Warranty 90 days 90 days 6 months 6 months 90 days
Price $28,600 $20,592 $27,664 $35,200 $42,328

Need expanded anterior segment scans? The Zeiss Anterior Segment Lens Kit for Cirrus OCT adds the external CORNEA and ANTERIOR CHAMBER lenses (requires the Anterior Segment Premier Module license on the instrument).

Questions about the Zeiss Cirrus 5000 HD-OCT? Contact us for availability and shipping details.

Additional information

Brand

You may also like…